COMMANDER 400 STICK & WIRE / | K867 / | K775 / |
|
| WARNING |
| |
Do not operate with panels open. |
| Keep guards in place. | |
Disconnect NEGATIVE |
| Keep away from moving parts. | |
before servicing. |
|
| Only qualified personnel should install,use |
Do not touch electrically live parts. |
| or service this equipment. |
CONNECTION | |
DIAGRAM: |
|
COMMANDER 400
14 | PIN |
|
AMPHENOL |
| |
TO | WORK | ELECTRODE |
|
| TO WORK |
CAUTION :
K867 UNIVERSAL
ADAPTER PLUG
ELECTRODE CABLE TO WIRE FEED UNIT
SPARE 82 81 42 41
31
32
2
4
21 GND
75
76
77
}N.D.
31
32
2
4
21 GND
GREEN
| 75 |
| 76 |
} | 77 |
|
N.E.
WIRE
FEEDER
K291 OR K404
INPUT CABLE
K775 OPTIONAL REMOTE CONTROL
DIAGRAMS
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPILICATIONS. SEE OPERATING MANUAL.
N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE "RANGE" SWITCH TO "WIRE WELDING CV". PLACE WIRE FEEDER SWITCH TO "WIRE FEEDER WITH CONTROL CABLE POSITION.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL / REMOTE SWITCH IN "REMOTE" POSITION. N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.E. SPLICE LEADS AND INSULATE.
S22915