COMMANDER 400 STICK & WIRE / LN-8 CONNECTION DIAGRAM
WARNING
Do not operate with panels open. | Keep | guards in | place. |
Disconnect NEGATIVE | Keep | away from | moving parts. |
before servicing. | Only qualified personnel should install,use | ||
Do not touch electrically live parts. | or service this equipment. |
CONNECTION | |
DIAGRAM: |
|
COMMANDER 400
14 PIN
AMPHENOL
TO WORK | ELECTRODE |
TO WORK
CAUTION :
TO
CABLE PLUG
K595 CONTROL CABLE
ELECTRODE CABLE
TO WIRE FEED UNIT
DIAGRAMS
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO "WIRE WELDING CV". PLACE LOCAL / REMOTE SWITCH IN "REMOTE" POSITION.