A-1

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - Commander 400

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

 

 

 

Make/Model

Description

Speed (RPM)

 

Displacement

Starting

Capacities

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

Deutz

3 cylinder

High Idle 1900

 

173 cu. in

12VDC battery

Fuel: 25 gal.

F3L 912 Diesel

44.2 HP(33kw)

Low Idle 1350

 

(2.827 L)

& Starter

94.6 L

Engine

@ 1800 RPM

Full Load 1800

 

 

 

 

 

Bore x Stroke

 

Oil: 8.5 Qts.

 

 

 

 

 

 

 

 

 

 

 

3.94” x 4.72”

 

8.04 L

 

 

 

 

 

 

 

 

 

 

 

 

(100mm x 120mm)

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

Duty Cycle

Welding Output

 

 

 

Volts at Rated Amps

 

100%

 

400 amps (DC Constant Current)

 

40 volts

 

 

 

400 amps (DC Constant Voltage)

 

40 volts

 

 

 

 

 

 

 

60%

 

500 amps (DC Constant Current)

 

40 volts

 

 

 

500 amps (DC Constant Voltage)

 

40 volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

 

 

Welding Range

 

Open Circuit Voltage

 

 

Auxiliary Power1

 

40 - 575 Amps

 

64-74 OCV

 

 

120/240 VAC

 

 

in 7 Ranges (Stick model)

 

 

 

 

10,000 Watts, 60 Hz.

 

or 8 Ranges (Stick & Wire model)

@1915 RPM

 

 

100% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT2

 

WIDTH

 

DEPTH

 

 

 

WEIGHT

 

42.0 in.

 

31.5 in.

 

63.1 in.

 

 

 

1650 lbs.(748 kg)

 

 

 

 

 

 

 

 

 

 

 

(Stick model)

 

1066.8 mm

 

800.1 mm

 

1602.7 mm

 

1683 lbs.(763 kg)

 

 

 

 

 

 

 

 

 

 

 

(Stick & Wire model)

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2. Top of Enclosure. Add 6.64” (168.7mm) for exhaust.

COMMANDER 400

Page 8
Image 8
Lincoln Electric IM544-B manual Installation, Bore x Stroke, Duty Cycle Welding Output Volts at Rated Amps