COMMANDER 400 STICK & WIRE / LN-25 ACROSS THE ARC CONNECTION DIAGRAM WITH OPTIONAL K857 REMOTE CONTROL

WARNING

 

Do not operate with panels open.

Keep guards in place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

CONNECTION

F-5

DIAGRAM:

 

COMMANDER 400

AMPHENOL 14 PIN

TO WORK

ELECTRODE

6 PIN

 

 

OPTIONAL K857

AMPHENOL

 

 

REMOTE CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LN-25

WIRE FEEDER

WORK CLIP LEAD

TO WORK

TO WORK

ELECTRODE CABLE

DIAGRAMS

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY.

N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL/REMOTE SWITCH IN "REMOTE" POSITION.

N.D. ON COMMANDER 400 STICK & WIRE, THE OUTPUT CONTROL SWITCH MUST BE IN THE "WELDING

TERMINALS ALWAYS ON" POSITION .

12-13-96

S22912

F-5

Page 37
Image 37
Lincoln Electric IM544-B manual Amphenol 14 PIN