COMMANDER 400

COMMANDER 400 STICK & WIRE TO K867 ADAPTER CONNECTION DIAGRAM

WARNING

Do not operate with panels open.

Keep

guards in

place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep

away from

moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

14 PIN

AMPHENOL

 

 

 

 

N.C.

 

 

 

 

 

 

 

81

 

 

 

 

 

82

NOT USED ON

COMMANDER 400 POWER SOURCES

 

 

 

 

 

 

 

 

SPARE

 

 

N.D.

 

K867 UNIVERSAL

2

CONNECT TOGETHER FOR WELDING OUTPUT

 

 

ADAPTER PLUG

4

N.C.

 

 

 

 

 

 

 

 

 

41

NOT USED ON

COMMANDER 400 POWER SOURCES

 

 

 

42

 

 

 

 

N.E.

 

 

 

31

 

 

 

 

115 VAC

 

 

 

 

32

 

 

TO WORK

ELECTRODE

 

 

 

 

 

 

 

 

 

GND

POWER SOURCE FRAME CONNECTION

 

 

 

21

WIRE FEEDER VOLTMETER CONNECTION

 

 

 

 

 

 

ELECTRODE CABLE

 

CONNECTS TO (WORK TERMINAL) OF POWER SOURCE

 

 

 

 

 

 

TO WIRE FEED UNIT

77

10K

 

 

 

 

 

 

 

 

TO WORK

76

REMOTE OUTPUT CONTROL

 

 

75

MIN.

 

 

 

 

 

 

 

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY.

 

 

 

 

 

 

 

 

 

 

 

N.C.

INSULATE EACH UNUSED LEAD INDIVIDUALLY.

 

 

2

 

 

 

 

 

 

 

TO

 

 

 

 

 

N.D.

FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION

TO

 

 

WIRE

 

 

 

 

 

 

 

 

 

 

 

RELAY TO CLOSE LEADS 2 & 4.

K867

 

 

FEEDER

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

N.E.

REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.

 

 

 

 

 

 

 

 

 

 

 

CONNECTION

F-9

DIAGRAM:

 

DIAGRAMS

6-12-98

S22916

F-9

Page 41
Image 41
Lincoln Electric IM544-B manual Electrode Cable