3-8. 115 Volts AC Duplex Receptacle
|
|
| 1 | 115 V 7 A AC Receptacle |
|
|
| Power is shared between duplex | |
|
|
| receptacle and Remote 14 recep- | |
|
|
| tacle (see Section | |
|
|
| 2 | Circuit Breaker CB1 |
|
|
| 3 | Circuit Breaker CB2 |
|
|
| CB1 protects 115 volts ac portion of | |
1 | 2 | 3 | duplex receptacle and Remote 14 | |
| receptacle from overload. | |||
|
|
|
CB2 protects 24 volts ac portion of Remote 14 receptacle from overload.
Press button to reset breaker.
Ref.
3-9. Electrical Service Guide
Input Voltage | 400 |
|
|
Input Amperes At Rated Output | 31 |
|
|
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes | 45 |
|
|
Min Input Conductor Size in AWG/Kcmil | 10 |
|
|
Max Recommended Input Conductor Length In Feet (Meters) | 264 (80) |
|
|
Min Grounding Conductor Size in AWG/Kcmil | 10 |
|
|
Reference: 1993 National Electrical Code (NEC). | |
|
|