3-7. Remote 14 Receptacle Information
A | J | |
B | K | I |
|
| |
C | L N | H |
D | M | G |
| E | F |
Ref.
| Socket* | Socket Information |
24 VOLTS AC | A | 24 volts ac. Protected by circuit breaker CB2. |
|
| |
| B | Contact closure to A completes 24 volts ac con- |
|
| tactor control circuit. |
115 VOLTS AC | I | 115 volts ac. Protected by circuit breaker CB1. |
|
| |
| J | Contact closure to I completes 115 volts ac con- |
|
| tactor control circuit. |
| C | Output to remote control; +10 volts dc in MIG |
|
| mode. |
| D | Remote control circuit common. |
REMOTE | E | 0 to +10 volts dc input command signal from re- |
OUTPUT | ||
CONTROL |
| mote control. |
| M | Mode select. |
| N | Remote inductance control. |
A/V | F | Current feedback; +1 volt dc per 100 amperes. |
AMPERAGE |
|
|
VOLTAGE | H | Voltage feedback; +1 volt dc per 10 arc volts. |
| ||
| G | Circuit common for 24 and 115 volts ac circuits. |
GND | K | Chassis common. |
|
*The remaining sockets are not used.