5-6. Lower Display
1
4
Wire Speed | Amps |
5
1
3
2
Non-CE Models
3
2
4
1 Lower Display
The lower display shows wire speed or amperage. The unit displays and adjusts only preset wire speed at idle. When the unit is in a welding state, actual wire speed is dis- played for the active welding sequence. If the amps display DIP is set in the display amps position (see Section
2 Lower Display Push Button
Press button to choose between wire speed or amperage functions.
3 Lower Display Push Button LED
The lower display push button LED illumi-
5
nates to indicate that information displayed can be changed by the Adjust control.
4Wire Speed LED
5Amps LED
The LEDs below the display illuminate to in- dicate which value is being shown.
•If the unit is in a welding state that does not involve feeding wire, the unit displays the weld sequence wire speed. At any time during welding, the weld sequence wire speed can be adjusted and overrides the preset wire speed display. In other words, if the Adjust control is activated while weld- ing, the unit displays and permits adjust-
CE Models
ment of the weld sequence wire feed speed regardless of the active welding se- quence.
•When the unit is displaying amperage, the Amps LED illuminates. Amperage is only displayed if the unit is in a welding state and the amperage is above a minimum value of 25 Amps.
•The display will read zero for amperage readings below the amperage threshold, prior to arc initiation. In addition, the am- perage display feature is disabled if the current detect override is in the On position (see Section
5-7. Setup Push Button
3
4
1
Trigger Hold Dual Schedule
3
24
2
1
Setup
| CE Models |
1 Setup Push Button
Press button to choose between trigger hold or dual schedule functions.
2Setup Push Button LED
3Trigger Hold LED
4Dual Schedule LED
•When the Setup button is pressed, the Set- up push button LED illuminates and the Trig- ger Hold LED flashes.
•The flashing LED indicates that the unit is in the trigger hold display mode. In this mode the upper display indicates HOLD and the lower display indicates the trigger hold sta-
tus On/Off. Use the Adjust control to change the trigger hold status or press the lower dis- play push button. If trigger hold is turned On, the trigger hold LED illuminates and stays On.
•When trigger hold is On, the user must press and hold the trigger for a predefined amount of time (the trigger hold delay time– see Section
•If a weld time is programmed, trigger hold is disabled.
•When the Setup button is pressed a second time, the dual schedule LED flashes. In this mode the upper display indicates DUAL and the lower display indicates dual schedule status On/Off. Use the Adjust control to change the dual schedule status if desired.
•Pressing the Setup button again exits the Setup mode. The dual schedule LED stops flashing to indicate the dual schedule status is Off.
•While in the Setup mode, the active program can be adjusted without deactivating the trigger hold Setup mode operation. If the trigger is activated, Setup mode(s) is termi- nated.