B. Installing Torch In Inverter Power Source

Label is located under terminal strip.

6

1

2

3

4

 

 

 

S-137 691

 

 

 

 

 

 

 

 

 

5

7

8

9

Tools Needed:

5/8 in

Turn Off power source, and disconnect input power plug. Open lower front access door.

 

 

 

1

Access Door

 

 

 

2

Strain Relief Clamp

 

 

 

3

Torch Cable

 

 

 

4

Torch (–) And Air/Gas Output

 

 

 

 

Connector

 

 

 

Connect torch cable as shown.

 

 

 

5

Terminal Strip1T

1

4

 

6

Connection Label

 

 

 

7

Pilot Arc/Shield Cup Detector

 

 

 

 

Lead 1

 

 

 

8

Shield Cup Detector Lead 2

 

 

 

9

Torch Switch Leads 3 And 4

 

 

 

Refer to label and connect leads as

 

 

 

shown.

 

 

 

Install strain relief clamp, and close

 

 

3

access door.

2

 

10

Work Cable (Supplied With

 

 

 

 

 

Power Source)

10

ST-128 701-C

Figure 3-3. Installing Torch In Inverter Power Source

SECTION 4 – OPERATING THE TORCH

WARNING

ELECTRIC SHOCK can kill.

 

 

ARC RAYS can burn eyes and skin;

Always wear dry insulating gloves.

 

 

NOISE can damage hearing.

 

 

 

 

Insulate yourself from work and ground.

 

 

Wear face protection with correct shade of filter.

Do not touch live electrical parts.

 

 

Wear correct eye, ear, and body protection.

 

 

 

 

 

Keep all panels and covers securely in place.

 

 

MOVING PARTS can cause injury.

 

 

 

 

 

Keep away from moving parts.

FUMES AND GASES can be hazardous

 

 

Keep all doors, panels, covers, and guards closed

to your health.

 

 

Keep your head out of the fumes.

 

 

 

 

and securely in place.

Ventilate area, or use breathing device.

 

 

See Safety Precautions at beginning of manual for ba-

Read Material Safety Data Sheets (MSDSs) and

 

 

sic cutting safety information.

 

manufacturer’s instructions for material cut.

 

 

 

 

CUTTING can cause fire or explosion.

Do not cut near flammable material.

 

Provide protection from flying sparks.

 

Watch for fire; keep extinguisher nearby.

 

Do not locate unit over combustible surfaces.

 

Do not cut on closed containers.

 

Allow work and equipment to cool before handling.

swarn6.1* 10/91

OM-1572 Page 4

Page 10
Image 10
Miller Electric APT-1000 manual Operating the Torch