Table 5-1. Cutting Trouble

Trouble

Remedy

Section

Sparks come out top of cut, or cut is not clean.

Arc goes out while cutting.

Arc goes on and off while cutting.

Torch travel speed too fast; reduce travel speed.

Check torch tip and electrode, and replace if necessary.

Metal being cut is too thick; increase power source Thickness control setting.

Make sure torch tip is touching metal while cutting.

Be sure work clamp is securely attached.

Torch travel speed is too slow; increase travel speed. Check torch tip and electrode, and replace if necessary.

Figure 4-2

5-2

*

Figure 4-2

*

Figure 4-2

5-2

*See power source Owner’s Manual.