2-1. Duty Cycle
CAUTION |
EXCEEDING DUTY CYCLE RATINGS will damage power source and torch. |
|
• Do not exceed indicated duty cycles. | warn7.1* 2/92 |
Duty cycle is how long the torch and power source can operate within a ten minute period without causing overheating or damage. This torch is rated at 60% duty cycle when operated at 10 amperes, allowing cutting 6 minutes out of 10. If the cutting amperes decrease, the duty cycle increases.
SECTION 3 – INSTALLATION
WARNING |
ELECTRIC SHOCK can kill.
• Do not touch live electrical parts.
• Turn Off power source, and disconnect input power before installing torch.
swarn3.1* 2/93
3-1. Consumables And Parts Supplied With Torch
Torch is shipped fully assembled and ready to install onto power source.
1
3
2
4
The following consumables are supplied with torch:
1Shield Cup
2Electrode
3Tip
4Wrench
Use supplied wrench to change tips and electrodes (see Section