Miller Electric CP-202 manual Inductance Selection 200 And 300 Ampere Models

Models: CP-202

1 28
Download 28 pages 7 b
Page 17
Image 17

2-7. Inductance Selection (200 And 300 Ampere Models)

2

1

5

4

3

6

7

1 Stabilizer Z

Tapped stabilizer Z is factory connected to the stabilizer tap which suits most GMAW applications.

Stabilizer Z controls the inductance applied to the weld current. To in- crease inductance and wet out the weld puddle, connect to stabilizer Z ending.

To change inductance proceed as follows:

2Lead 25

3Stabilizer Z Tap

4Stabilizer Z Ending

5Lead 26

To increase inductance, connect lead 26 to stabilizer ending and secure.

Reinstall side panel.

6Typical Weld Bead Using The Tap Stabilizer Connection

Use the tap Stabilizer connection to obtain arc type and weld bead suit- able for some mild steel applica- tions.

7Typical Weld Bead Using The End High Stabilizer Connection

Use the end Stabilizer connection to reduce weld bead crowning, and spread the weld puddle.

Weld Bead Using The Tap Stabilizer

Weld Bead Using The End Stabilizer

Connection With 17 Volts, 100 Amps

Connection With 17 Volts, 100 Amps

3/8, 7/16 in

3/8 in

ST-801 379-B

OM-259 Page 13

Page 17
Image 17
Miller Electric CP-202 manual Inductance Selection 200 And 300 Ampere Models