SECTION 2 − INSTALLATION
2-1. Specifications
|
|
| Open- | Amperes Input at Rated Load Output, 50 or 60 Hz, |
|
| |||||||||
|
| Rated | Circuit |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Model |
| Welding | Voltage | 200 | 220 | 230 | 380 | 400 | 440 | 460 | 520 | 575 |
|
| |
|
| Output | Range | KVA | KW | ||||||||||
|
| V | V | V | V | V | V | V | V | V | |||||
|
|
| DC |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 200 A @ 28 |
| 21.9 | 19.1 | 19 | 12 | 10.5 | 9.5 | 9.5 | 8.8 |
| 7.6 | 7.2 | |
200Amp |
| Volts DC, 100% | 14−39 | −− | |||||||||||
| 3* | 2.8* | 2.7 | 1.9* | 1.6* | 1.5* | 1.4* | 1.1* | 0.97* | 0.68* | |||||
|
| Duty Cycle |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 250 A @ 35 |
| 34.5 |
| 30 |
|
|
| 15 |
|
| 11.9 | 11.2 | |
250 Amp | Volts DC, 100% | 14−44 | −− | −− | −− | −− | −− | −− | |||||||
1.7* | 1.4* | 0.7* | 0.57* | 0.42* | |||||||||||
|
| Duty Cycle |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 300 A @ 32 |
| 38 | 34.5 | 33 | 20 | 19 | 17.3 | 16.5 | 14.6 | 13.0 | 13.1 | 12.3 | |
300 Amp | Volts DC, 100% | 14−44 | |||||||||||||
3* | 2.8* | 2.7* | 1.9* | 1.6* | 1.5* | 1.4* | 1.1* | 0.7* | 0.97* | 0.68* | |||||
|
| Duty Cycle |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
*While idling |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min- utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.
Y Exceeding duty cycle can damage unit and void warranty.
100% Duty Cycle
| Continuous Welding |
Overheating |
|
0 | A/V |
| 15 |
| OR |
Minutes | Reduce Duty Cycle |
|
duty1 4/95 / Ref.