SECTION 2 − INSTALLATION

2-1. Specifications

 

 

 

Open-

Amperes Input at Rated Load Output, 50 or 60 Hz, Three-Phase

 

 

 

 

Rated

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Welding

Voltage

200

220

230

380

400

440

460

520

575

 

 

 

 

Output

Range

KVA

KW

 

 

V

V

V

V

V

V

V

V

V

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 A @ 28

 

21.9

19.1

19

12

10.5

9.5

9.5

8.8

 

7.6

7.2

200Amp

 

Volts DC, 100%

14−39

−−

 

3*

2.8*

2.7

1.9*

1.6*

1.5*

1.4*

1.1*

0.97*

0.68*

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250 A @ 35

 

34.5

 

30

 

 

 

15

 

 

11.9

11.2

250 Amp

Volts DC, 100%

14−44

−−

−−

−−

−−

−−

−−

1.7*

1.4*

0.7*

0.57*

0.42*

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300 A @ 32

 

38

34.5

33

20

19

17.3

16.5

14.6

13.0

13.1

12.3

300 Amp

Volts DC, 100%

14−44

3*

2.8*

2.7*

1.9*

1.6*

1.5*

1.4*

1.1*

0.7*

0.97*

0.68*

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can weld at rated load

without overheating.

If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.

Y Exceeding duty cycle can damage unit and void warranty.

100% Duty Cycle

 

Continuous Welding

Overheating

 

0

A/V

 

15

 

OR

Minutes

Reduce Duty Cycle

 

duty1 4/95 / Ref. SA-177 714-A

OM-259 Page 9

Page 13
Image 13
Miller Electric CP-202 manual Installation, Specifications, Duty Cycle And Overheating