3-3. Remote 14 Receptacle RC14 Information and Connections

1

 

 

 

 

4

 

A K

J I

5

 

B

 

 

 

 

C

L N

H

 

 

D

M

G

 

 

 

E

F

 

2

3

 

 

 

 

 

1Front Panel

2Plug

3Threaded Collar

4Keyway

5Remote 14 Receptacle RC14 (See Section 3-4)

To connect to receptacle, align key- way, insert plug, and tighten threaded collar.

 

 

sb7.1* 3/93 - Ref. S-0004-A / Ref. S-0750 / Ref. ST-801 826-C

3-4. Remote 14 Socket Information

 

 

 

 

Socket

Socket Information

 

 

 

Remote Contactor

A

+24 volts dc.

B

Contact closure to A completes 24 volts dc contactor control circuit.

 

 

 

 

 

C

Command reference; +10 volts dc.

Remote Output Control

D

Control circuit common.

E

Input command signal (potentiometer wiper or 0 to +10 volts dc).

 

 

G

Not used.

 

 

 

Power Source Limit

F, J

Absence of internal contact closure between F and J signals power source failure to remote

control device.

 

 

 

 

 

 

H

Coil loss compensation value.

 

I

Actual frequency output signal (1 volt/10 kHz).

Remote Metering

L

Average power output signal (1 volt/5 kW).

M

Voltage output signal RMS (1 volt/100 volts).

 

 

N

Current output signal RMS (1 volt/100 amperes).

 

K

Chassis common.

 

 

 

OM-184 227 Page 8

Page 12
Image 12
Miller Electric Intellifire 250 manual Remote 14 Receptacle RC14 Information and Connections, Remote 14 Socket Information