Miller Electric Intellifire 250 manual Measuring Tuning Capacitor Voltage

Models: Intellifire 250

1 32
Download 32 pages 23.29 Kb
Page 16
Image 16

5-5. Measuring Tuning Capacitor Voltage

Y Significant AC voltage can remain on capacitors after unit is Off. Always check ALL capacitors as shown to be sure they have discharged before working on unit.

4

1

2

3

Top View

Tools Needed:

3/8 in

Turn Off power source and disconnect input power.

Remove wrapper.

1Tuning Capacitor C1

2Tuning Capacitor C2

3Tuning Capacitor C3

4Voltmeter

Check tuning capacitors.

Measure the ac voltage across the terminals on capacitors every 30 seconds until voltage is near 0 (zero) volts.

Proceed with job inside unit. Reinstall wrapper when finished.

Ref. ST-801 826-A

OM-184 227 Page 12

Page 16
Image 16
Miller Electric Intellifire 250 manual Measuring Tuning Capacitor Voltage