SECTION 2 – INSTALLATION

2-1. Specifications

 

 

 

 

 

 

 

 

Amperes Input at

 

 

 

 

 

 

Rated Welding

Amperage

Maximum

 

Rated Load

 

 

 

 

 

Overall

 

Output, 60 Hz,

 

 

 

 

Weight

Open-Circuit

 

 

 

 

 

Output

 

Range

 

Single-Phase

 

 

 

 

Dimensions

 

Voltage DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 V

230 V

KVA

KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length: 36 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(915 mm)

150 A @ 23 Volts

30 – 185

 

33

 

30 (1.6)*

26 (1.4)*

6 (0.27)*

5 (0.13)*

 

165 lb

Width: 18 in

DC, 60% Duty Cycle

 

 

 

(75 kg)

(457 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height: 27 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(686 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Type And Diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculated Wire Speed

 

 

Max Wire Feed Speed

Solid Steel /

 

 

 

 

 

 

 

 

 

 

 

 

 

Range At No Load

 

 

 

While Welding

Stainless

Flux Cored

Aluminum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.023 – .035 in

.030 – .045 in

.030 – .035 in

 

138 – 795 IPM (3.5 – 20.3 m/min)

 

650 IPM (16.5 m/min)

(0.6 - 0.9 mm)

(0.8 – 1.2 mm)

(0.8 – 0.9 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Temperature Range – –20C to +40C

 

 

 

 

Storage Temperature Range – -30C to + 50C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2. Volt-Ampere Curves

Volt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown.

va_curve1 4/95 – SB-180 824

OM-1313 Page 5

Page 9
Image 9
Miller Electric OM-1313 manual Installation, Specifications, Volt-Ampere Curves