5-2. Overload Protection
1
2
YTurn Off wire feeder and welding power source. Stop
engine on welding generator.
1Circuit Breaker CB1
2Fuse F1
CB1 and F1 protect wire feeder from overload. Correct problem and reset CB1 or replace F1.
Close and latch door.
Ref. 800
5-3. Troubleshooting Table
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | ||
|
|
| |||
|
|
| |||
Wire does not feed, unit completely inop- |
| Turn Power switch On. | |||
erative. |
|
| |||
| Check fuse F1 and replace if necessary (see Section | ||||
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Check |
|
|
|
|
|
|
|
|
|
|
| Check input power. |
|
|
| |||
Wire does not feed. |
| Check circuit breaker CB1 and fuse F1. (see Section | |||
|
|
|
|
|
|
|
|
|
|
| Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s |
|
|
|
|
| Manual. |
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check drive motor and control board PC1. |
|
|
| |||
Wire feeds erratically. |
| Readjust hub tension and drive roll pressure (see Section | |||
|
|
|
|
|
|
|
|
|
|
| Use correct size drive roll (see Parts Listing). |
|
|
|
|
|
|
|
|
|
|
| Clean or replace dirty or worn drive roll (see Section |
|
|
|
|
|
|
|
|
|
|
| Remove weld spatter around nozzle opening. |
|
|
|
|
|
|
|
|
|
|
| Replace contact tip or liner. See gun Owner’s Manual. |
|
|
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check drive motor and control board PC1. |
|
|
| |||
Wire feeds when Jog switch is pressed |
| Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s | |||
but not when gun trigger is pressed. |
| Manual. | |||
|
|
| |||
Wire feeds as soon as power is applied. |
| Check gun trigger. See gun Owner’s Manual. | |||
|
|
| |||
Wire does not feed until trigger is |
| Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads. | |||
pressed but continues to feed after trig- |
|
| |||
ger is released. |
|
| |||
|
|
| |||
Gas valve rattles loudly and wire feeds |
| Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads. | |||
slowly or erratically. |
|
| |||
|
|
| |||
Gas does not flow; wire feeds. |
| Check gas valve and flowmeter. | |||
|
|
| |||
|
|