5-6. Installing And Threading Welding Wire

Install wire spool. Adjust tension nut so

Install wire guides and

wire is taut when wire feed stops.

anti-wear guide.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

Indicator

Pressure

Scale

Adjust

 

Rear

Pressure

Rolls

Adjust

 

 

Front

 

Rolls

No Wire Slip

NONCONDUCTIVE

SURFACE

Drive Rolls

Gun Cable

End Of Liner

Install drive rolls.

Wire Slips

NONCONDUCTIVE

SURFACE

Tools Needed:

3/16, 5/64 in

15/16, 3/8 in

. Be sure that outlet cable has proper size

. For soft wire or small diameter stainless

. To adjust drive roll pressure, hold nozzle

liner for the welding wire size. When

steel wire, reduce drive roll pressure on

about 2 in (51 mm) from nonconductive

installing gun,

position

liner

the rear roll to half that of the front rolls.

surface and press gun trigger to feed wire

extending from outlet wire guide as

 

against surface. Tighten knob so wire

close as possible to drive rolls without

 

does not slip. Do not overtighten. If con-

touching.

 

 

 

tact tip is completely blocked, wire should

Install gun. Lay gun cable out straight. Cut off

 

slip at the feeder (see pressure adjust-

 

ment above).Cut wire off. Close cover.

end of wire. Push wire through guides up to

 

 

drive rolls; continue to hold wire. Press Jog

 

 

button to feed wire out gun.

 

 

 

Ref. 156 929-A / Ref. 150 922 / Ref. 156 930 / 802 954 / S-0627-A

OM-1500-9 Page 14

Page 18
Image 18
Miller Electric S-74DX manual Installing And Threading Welding Wire, Extending from outlet wire guide as