4-2. Setting Digital Meter Board PC4 DIP Switches

1

2

3Meter DIP switches are factory set to display wirefeed speed and voltage using 14 pin feedback. Meter hold feature is factory set to off position.

Wire Feed Speed Display

Inches Per Minute

Meters Per Minute

 

S1

 

S1

S2

S2

S2

S2

14 Pin

Voltage/Current

14 Pin

Voltage/Current

Voltage

Sense Kit

Voltage

Sense Kit

Feedback

(195194)

Feedback

(195194)

1Front Meter Panel

2S1 DIP Switch

3S2 DIP Switch

If the DIP switches are set to a Meter Hold (ON) position, the meter value will hold 5 seconds after gun is trig- gered. The meter value will continue to hold for 8 seconds after trigger is released or until gun is re-triggered.

.When using power sources without 14 pin voltage/current feedback − optional remote voltage/current kit 195194 is required.

Indicates this DIP switch setting has no effect on this function.

 

Meter Hold

(ON)

(OFF)

S1

S1

Amps Display

S2

S2

14Pin

Current Feedback

Voltage/Current Sense Kit (195194)

803 141/ Ref. 803 124

OM-215 092 Page 13

Page 17
Image 17
Miller Electric UWF-SC12RC Setting Digital Meter Board PC4 DIP Switches, Wire Feed Speed Display, Meter Hold, Amps Display