Milwaukee 2270-20 Functional Description, Work Area Safety Service, Personal Safety, Symbology

Models: 2270-20

1 9
Download 9 pages 12.39 Kb
Page 2
Image 2

IMPORTANT SAFETY INSTRUCTIONS

FUNCTIONAL DESCRIPTION

WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.

Save these instructions - This operator’s manual contains important safety and operating instructions for the MILWAUKEE Contact Temp Meter. Before using, read this operator’s manual and all labels on the meter.

WORK AREA SAFETY

SERVICE

1

9

10

16

15

1. Display

 

 

 

2. Power ON/OFF

 

 

3. °C or °F selector

 

 

 

 

4. Hold button

 

14

5. Mode selector

 

 

6. START STOP button

•Keep children and bystanders away while operating meter. Store idle Contact Temp Meters out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate them.

•Avoid dangerous environments. Do not use in rain or snow. Do not immerse meter in water or allow water to flow into the meter. Do not use in the presence of explosive atmospheres (gaseous fumes, dust or flammable materials) because sparks may be generated when inserting or remov- ing batteries, possibly causing fire.

PERSONAL SAFETY

•Have your meter serviced by a qualified repair person using only identical replacement parts.

This will ensure that the safety of the tool is main- tained.

•Do not disassemble. Incorrect reassembly may result in the risk of electric shock or fire. If it is dam- aged, take it to a MILWAUKEE service facility.

•Store in a cool, dry place. Do not store where temperatures may exceed 140°F (60°C) such as in direct sunlight, a vehicle or metal building during the summer.

•Do not remove or deface labels. Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE

2

3

4

5

11

12

7 13

6

7. MIN MAX AVG button

8.T1 and T2 inputs

9.Battery life indicator

10.Primary measurement

8

11. Elapsed time total

12.Time MIN MAX

13.Hold indicator

14. Secondary measurement

15. °C or °F indicator

16. Delta T1-T2 indicator

•Stay alert, watch what you are doing and use common sense when operating meter. Do not use while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention may result in serious personal injury.

•Do not overreach. Keep proper footing and balance at all times. This enables better control in unexpected situations.

•Never connect the probe to an energized circuit.

BATTERY USE AND CARE

This tool is designed to be powered by 3-AA batteries properly inserted into the MILWAUKEE meter. Do not attempt to use with any other voltage or power supply.

•Donotleavebatterieswithinthereachofchildren.

Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.

•Do not mix rechargeable and non-rechargeable batteries.

•Install batteries according to polarity (+ / –) diagrams.

•Properly dispose of used batteries immedi- ately.

•Do not incinerate or dismantle batteries.

Under abusive conditions, liquid may be eject- ed from the battery, avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help.

Liquid ejected from the battery may cause irritation or burns.

service facility for a free replacement.

SYMBOLOGY

Read Operator’s Manual

Earth

Danger, Warning, or Caution - Consult the operators manual for additional safety information.

Battery compartment

European Conformity Mark

Do not dispose of this product as unsorted municipal waste.

Specifications

Contact temp range: -200°C to 1372°C (-328°F to 2501°F)

Accuracy

For ambient temperatures 18°C to 28°C (64°F to 82°F)

Measurements from -100°C to 1372°C (-148°F to 2501°F)

±(0.1% of reading + 0.7°C)/(0.1% of reading +1.3°F) Measurements from -200°C to -100°C (-328°F to -148°F)

±(0.4% of reading +0.7°C)/(0.4% of reading +1.3°F)

Temperature Coefficient

Measurements from -100°C to 1372°C (-148°F to 2501°F)

(0.01% of reading + 0.05°C) per degree C outside 18°C to 28°C ambient (0.0056% of reading +0.05°F) per degree F outside of 64°F to 82°F ambient Measurements from -200°C to -100°C (-328°F to -148°F)

(0.04% of reading + 0.05°C) per degree C outside 18°C to 28°C ambient (0.022% of reading +0.05°F) per degree F outside of 64°F to 82°F ambient

Contact temp display resolution: 0.1°C/°F

K-Type Probe temp range: -60°C to 200°C (-76°F to 392°F)

K-Type Probe temp input accuracy: ±1.1°C or ±0.4% of reading, whichever is greater

Drop: 1 meter

Operating temperature: -10°C to 50°C (14°F to 122°F)

Storage temperature: -40°C to 60°C (-40°F to 140°F)

Relative humidity: 10 to 90% RH non-condensing at <30°C (<86°F) ambient

Battery: 3 AA batteries, LR6, 4.5V DC

Battery life: Greater than 80 hrs with all functions

Safety Compliances .... EN61326-1,2; IEC61000-3-2,3; IEC61000-4-2,3,4,5,6; CISPR11; FCC Part 15

Certifications .... CE

2

3

Page 2
Image 2
Milwaukee 2270-20 manual Functional Description, Work Area Safety Service, Personal Safety, Battery USE and Care, Symbology

2270-20 specifications

The Milwaukee 2270-20 is a cutting-edge tool designed for professionals and serious DIY enthusiasts alike, known for its efficiency and high-performance capabilities. This compact, portable device is engineered to deliver accurate measurements and enhance productivity on job sites, making it an essential addition to any toolkit.

One of the standout features of the Milwaukee 2270-20 is its advanced digital laser technology. The device includes a precise laser that provides quick and accurate measurements up to 100 feet, allowing users to make calculations with confidence. This technology not only improves measurement accuracy but also optimizes workflow by reducing the time spent on manual measuring and marking.

The Milwaukee 2270-20 is equipped with an intuitive interface, featuring a backlit display for easy readability, even in low-light conditions. This user-friendly setup allows professionals to quickly switch between various measurement modes, such as horizontal, vertical, and area calculations, ensuring versatility across a multitude of tasks.

Battery life is crucial for any handheld tool, and the Milwaukee 2270-20 does not disappoint. It operates on a long-lasting battery that can sustain hours of continuous use. Additionally, the compact design of the tool enhances its portability, making it easy to carry around job sites without the bulk of traditional measuring tools.

Durability is another key characteristic. The Milwaukee 2270-20 is built to withstand the rigors of everyday construction environments. Its rugged exterior is designed to resist impact and harsh conditions, ensuring that it remains functional and reliable even in challenging situations.

Furthermore, the Milwaukee 2270-20 integrates seamlessly with other Milwaukee products, thanks to its compatibility with the One-Key system. This technology not only allows for inventory tracking but also provides users with the ability to customize settings and track usage metrics, thereby improving organization and efficiency.

In conclusion, the Milwaukee 2270-20 merges advanced measuring capabilities with user-friendly features and exceptional durability, making it an ideal choice for professionals seeking precision and reliability on the job. Whether you are measuring distances, calculating areas, or tracking project metrics, this innovative tool is designed to meet the needs of modern tradespeople and enhance productivity across various applications.