Wiring Diagrams

Wiring diagrams are provided here for refer- ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.

CAUTION

Label all wires prior to discon- nection when servicing con- trols. Wiring errors can cause improper and dangerous appli- ance operation.

Millivolt Wiring Diagram

Schematic Representation Only

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105o C - 18 gage wire.

TP

TH TP

Thermopile

TH

 

*Optional Switch

 

 

Field Wired

 

Factory

 

Wired

Standard OFF/ON Switch

*OptionalKitsInstalled-OFF/ONwallswitch, wall thermostat or remote control receiver. Note: Turn the appliance-mounted OFF/ON burner control switch to the OFF position if any of these kits are installed.

Figure 16

 

Plug blower

Green

 

 

 

 

into this

 

White

 

Ground - Green

 

 

 

 

 

receptacle

 

 

 

 

Neutral - White

 

 

 

 

Black

120 VAC - Black

 

 

 

 

 

Blower

 

 

 

 

 

Junction Box

 

 

 

 

 

 

 

 

 

 

 

 

* Wall-mounted

 

Ground

 

 

 

Tab

ON/ OFF Blower

 

 

 

 

 

Switch or Variable

 

Tab Intact

 

 

 

Broken

Speed Control Switch.

 

 

 

 

Red

 

 

Green

 

Neutral

Hot

 

J-BOX WIRING FOR

 

Ground

 

 

WALL SWITCH

 

 

Side of

Side of

 

Screw

 

BLOWER CONTROL

 

 

Receptacle

Receptacle

View A

 

 

 

 

 

J-Box Wiring when

 

Relay Module C/W FBK-250 only. Plug blower

 

using unit mounted

 

 

 

into J-Box receptacle for FBK-100 or FBK-200

 

relay module.

 

 

 

application. See View A for J-Box wiring.

 

 

 

 

 

BK

VAC

 

 

 

 

 

W

 

 

 

 

 

120

 

 

 

 

 

G

 

Optional Blower

 

 

Junction Box

 

 

 

 

 

 

 

 

*OFF/ON Switch

 

 

Pilot Burner

 

 

(Integral with

 

 

 

Assembly

 

 

Gas Valve)

 

 

 

 

 

 

Honeywell

 

 

 

 

 

 

Electronic

 

 

 

 

 

 

Gas

 

 

 

 

 

 

Valve

 

 

 

 

Igniter

 

 

 

 

* Leave the OFF/ON switch, which is

 

Connector

 

 

 

GROUND

integral with the gas valve, in the ON

BL

 

 

 

Transformer

position.

 

 

 

 

 

** Optional Control Switches: Wall

BL BK

 

 

 

 

 

Switch, Wall Thermostat or Remote

 

 

R

BL

 

Control Receiver.

 

 

 

24 V

120 VAC

 

 

 

BK

Secondary

Notes:

 

 

Primary

 

 

 

 

 

 

 

 

 

1. If any of the original wire as supplied

 

 

 

 

 

 

must be replaced, use Type AWM 105°C

 

 

 

BK

BK = BLACK

BL = BLUE

- 18 gage wire ONLY.

Optional Control Switch

 

2. 120 VAC, 60 Hz - Less than 3 Amps.

 

 

R = RED

W = WHITE

 

 

 

W

Caution: label all wires prior to

 

 

 

G = GREEN

 

 

 

 

 

 

disconnection when servicing controls.

 

 

 

 

Field Wired

 

 

 

 

Wiring errors can cause improper and

 

 

 

 

Factory

dangerous operation.

 

 

 

 

Wired

 

Schematic Representation Only

Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits

Figure 17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Page 12
Image 12
Milwaukee LMDVT-3328CNM Wiring Diagrams, Millivolt Wiring Diagram Schematic Representation Only, Standard OFF/ON Switch