Milwaukee LMDVT-3328CNM manual Table of Contents

Models: LMDVT-3328CNM

1 28
Download 28 pages 19.01 Kb
Page 2
Image 2

Congratulations!

In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most dependable fireplace to be found anywhere. Its a beautiful, prestigious alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX Fireplace Owners.

Please carefully read and follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.

Theseappliancesaredesignedtooperateonnatural gas or propane gas only. The use of other fuels or combinationoffuelswilldegradetheperformance of this system and may be dangerous.

Millivolt Models - BTU Input

Millivolt models come standard with the manu- ally-modulated gas valve; flame appearance and heat output can be controlled at the gas valve. The BTU Input for millivolt models is shown in Tables 1 & 2:

TABLE OF CONTENTS

 

 

Introduction

Page

2

General Information

Page

2

Gas Controls Access

Page

3

Operation/Care of Your Appliance

Page

3

Variable Flame Adjustment

Page

4

Maintenance

Page

5

Front Glass Enclosure Panel,

 

 

Removal and Installation

Page

6

Install Vermiculite, Volcanic Stone,

 

 

Embers & Logs

Page

7

Burner Flame Appearance & Sooting Page 10

Burner Flame Adjustments

Page 10

Millivolt Appliance Checkout

Page

11

Electronic Appliance Checkout

Page

11

Product Reference Information

Page

11

Warranty

Page 11

Wiring Diagrams

Page 12

Accessory Components

Page 13

Lighting Instructions – Millivolt

Page

18

Lighting Instructions – Electronic

Page

20

Maintenance Schedule

Page 22

Troubleshooting Guide – Millivolt

Page

23

Troubleshooting Guide – Electronic...

Page

23

Replacement Parts List

Page

26

This manual is part of a set of two supporting this product. Refer to manual 850,029M for Installation Instructions.

Introduction

The Fireplace models covered in this manual are Direct-Vent sealed combustion gas fireplace heaters designed for residential application. Direct-Vent appliances operate with the com- bustion chamber completely isolated from the indoor environment. All air for combustion is brought in from the outside and exhaust gases are vented through the same direct vent, co-axial (intake/exhaust) vent system.

The Millivolt appliances have a millivolt gas control valve with piezo ignition system provides safe, efficient operation. If any optional acces- sories which require electrical power are being installed, the electrical power must be provided at the time of appliance installation.

The Electronic appliances have an electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these appliances.

These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-F-31-5) to ANSI ZZ21.88b (in Canada, CSA-2.33b), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters.

The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest edition, or the Natural Gas and Propane Installation Code, CSA B149.1-latest edition. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1 - latest editions.

General Information

Note: Installation and repair should be per- formed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc.

It is imperative that the control compartment, burners and circulating air passage ways of appliance be kept clean. See Maintenance instructions on Page 5.

S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil.

Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. Locate furniture and window coverings accordingly.

These fireplaces are designed as supplemental heaters. Therefore, it is advisable to have an alter- nate heat source when installed in a dwelling.

Input (BTU) MAnnually-Modulated Gas Valves (millivolt models)

NATURAL GAS

Models

Input Rate

 

(BTU/HR)

 

 

LMDVT-3328CNM

17,500 high

LMDVR-3328CNM

11,700 low

 

 

LMDV-3530CNM

20,000 high

12,800 low

 

 

 

LMDV-4035CNM

27,000 high

18,500 low

 

Table 1

Input (BTU) MAnnually-Modulated Gas Valves (millivolt models)

PROPANE GAS

Models

Input Rate

 

(BTU/HR)

 

 

LMDVT-3328CPM

17,500 high

LMDVR-3328CPM

14,000 low

 

 

LMDV-3530CPM

20,000 high

15,200 low

 

 

 

LMDV-4035CPM

27,000 high

21,500 low

 

Table 2

Electronic Models -

Electronic models have a fixed rate gas valve. The BTU Input for electronic models is shown

in Table 3:

Input (BTU) - Fixed Rate

(electronic models)

NATURAL GAS & PROPANE GAS

Models

Input Rate

 

(BTU/HR)

 

 

LMDVT-3328CNE

17,500

LMDVR-3328CNE

 

 

 

LMDV-3530CNE

20,000

 

 

LMDV-4035CNM

28,000

LMDV-4035CPM

 

 

 

Table 3

Page 2
Image 2
Milwaukee LMDVT-3328CNM manual Table of Contents