Back Panel

Buzzer On/Off Switch: The default position of the buzzer switch is OFF. If you want to enable this function, there is a button inside the hole, please insert a paper clip or small pointed object into the hole and press the button. In case of utility failure (on battery), it will emit a long beep. In case of low battery, it will emit a short beep.

Communication Signals

The communication signals of this unit are isolated from the internal circuitry via open collector Opto-coupled transistors. The connection “SIG RTN” (Signal Return) is a common return point for all communication signals. In the typical application, the attached equipment digital ground connects to Signal Return, and pull-up resistors turn the open collector signals into logic levels.

Signal

Message

12V

+ Voltage output

12V RTN

- Voltage output

SIG RTN

Signal return

ON BATTERY

Low when operating from utility line.

 

Open when operating from battery.

REPLACE

Low when battery is charged.

BATTERY

Open when battery fails the Self Test.

BATTERY

Low when battery is present.

MISSING

Open when battery is missing.

LOW

Low when battery is near full charge capacity.

BATTERY

Open when operating from a battery with < 20% capacity.

SPECIFICATION

Model

ParaShield 1224

 

 

Input

 

Voltage Range

85Vac – 264Vac (Universal Input)

Frequency Range

47 – 70 Hz

Output

 

On Battery Output Voltage

12VDC

Continuous Power Capability

24Watts

Output Power Max

24Watts

Efficiency (at 75% Load)

> 75 %

Battery

 

Battery Type

Sealed, Maintenance Free Lead-Acid Battery

Numbers of Battery

1-12V7.2AH

Typical Recharge Time

18-Hours

Replaceable

Yes

Surge Protection and Filtering

 

Lightning / Surge Protection

Yes

Warning Diagnostics

 

Indicators

AC, Output, Battery

Management

 

Auto-Charge

Yes

Communication Interface

On Battery, Replace Battery, Battery Missing,

 

Low Battery

Physical

 

Net Dimensions (L*W*D)

16.7cm x 24cm x8.1cm

Net Weight (kg)

3.28

Environment

 

Operating Temperature

32oF – 104oF (0-40oC)

Operating Humidity

0 – 95% noncondensing within enclosure

Max Operating Elevation

10,000ft (3,000m)

Max Storage Elevation

50,000ft (15,000m)

Storage Temperature

5oF – 113oF (-15oC – 45oC)

Cold Start

The cold start feature is for applying power to the DC UPS and connected equipment when the DC UPS is off and there is no utility power. Before using the cold start feature, please make sure the battery is charged. To start the cold start feature, press the recessed cold start button with a small pointed object.

FCC Notice:

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a

particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help. Any special accessories needed for compliance must be specified in the instruction.

CAUTION: A shielded-type power cord is required in order to meet FCC emission limits and to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment.

CAUTION: Any changes or modifications not expressly approved by MINUTEMAN UPS could void the authority granted by the FCC to operate this equipment. For more information,

please contact: MINUTEMAN UPS: Phone: (800) 238-7272, (972) 446-7363, Fax: (972) 446-9011, www.minutemanups.com

LIMITED WARRANTY

Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials (excluding the batteries) or workmanship for a period of three years from the date of original purchase by the end user. Para Systems Inc. (Para Systems) warrants the Batteries for a period of two years from the date of purchase. For equipment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems. Repair will be from the nearest authorized service center. Replacement parts and warranty labor will be borne by Para Systems. For equipment located outside of the United States and Canada, Para Systems only covers faulty parts. Para Systems products repaired or replaced pursuant to this warranty shall be warranted for the remaining portion of the warranty that applies to the original product. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. The warranty shall be void if (a) the equipment is damaged by the customer, is improperly used, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications; (b) the equipment is repaired or modified by anyone other than Para Systems or Para Systems-approved personnel; or (c) has been used in a manner contrary to the product's operating manual or other written instructions. Any technical advice furnished before or after delivery in regard to use or application of Para Systems’s equipment is furnished without charge and on the basis that it represents Para Systems’s best judgment under the circumstances, but it is used at the recipient's sole risk. EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation of implied warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para Systems is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost of substitutes, claims by third parties, or otherwise. The sole and exclusive remedy for breach of any warranty, expressed or implied, concerning Para Systems’s products and the only obligation of Para Systems hereunder, shall be the repair or replacement of defective equipment, components, or parts; or, at Para Systems’s option, refund of the purchase price or substitution with an equivalent replacement product. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.

PN-34000247 Rev0

Page 2
Image 2
Minuteman UPS PN-34000247 user manual Communication Signals, Specification, Cold Start, Limited Warranty

PN-34000247 specifications

The Minuteman UPS PN-34000247 is a reliable uninterruptible power supply designed to protect sensitive electronics and critical systems from power disturbances. With a focus on providing uninterrupted power, the Minuteman UPS employs a range of advanced technologies and features to ensure the safety and efficiency of connected devices.

One of the standout features of the PN-34000247 is its robust battery management system. The UPS is equipped with a high-performance lead-acid battery that provides ample backup power during outages. This ensures that connected equipment continues to function seamlessly even in the event of a power failure. The intelligent battery management system also monitors battery health, providing alerts for maintenance and ensuring optimal performance.

The Minuteman UPS PN-34000247 incorporates advanced surge protection technology. This feature safeguards sensitive electronics from power surges and spikes, which can cause irreparable damage. The device includes multiple outlets, allowing users to connect several devices while maintaining surge protection across all of them.

Another key characteristic of the Minuteman UPS is its ability to provide automatic voltage regulation (AVR). This technology helps to stabilize voltage levels, ensuring that connected devices receive a consistent power supply. Fluctuations in voltage can lead to system malfunctions or failures, and the AVR feature minimizes these risks by correcting low or high voltage inputs automatically.

The UPS also features an LCD display that provides real-time data on power conditions. Users can monitor battery status, load levels, and input/output voltages, allowing for informed decision-making regarding power management. This transparency helps users understand the operational status of their UPS and take necessary actions in case of abnormalities.

Furthermore, the Minuteman UPS PN-34000247 offers various communication options. It can be integrated with network management systems, enabling remote monitoring and management of power conditions. This is particularly advantageous for businesses that need to maintain critical systems with minimal downtime.

Designed with energy efficiency in mind, the Minuteman UPS adheres to modern energy standards, reducing its impact on the environment while saving on electricity costs. With its compact footprint and reliable performance, the PN-34000247 is an ideal solution for small businesses, home offices, and other settings where power continuity is essential.

In summary, the Minuteman UPS PN-34000247 combines advanced technologies and features such as intelligent battery management, automatic voltage regulation, surge protection, and real-time monitoring to provide top-notch power management solutions. Its design caters to users’ needs for reliability, efficiency, and ease of use, making it a valuable addition to any power-sensitive environment.