Current Loadcell Bits
Follow
Instructions
Once in “Scale Calibration”, enter in the scale calibration weight value stamped on the side of the weight.
The controller will prompt you to remove the weight hopper and press OK. After touching OK, the controller will display “PLEASE WAIT...”
Next, the controller will ask you to hang the calibration weight on the right loadcell bracket (loadcell A) and press OK.
The controller will ask you to hang the calibration weight on the left loadcell bracket (loadcell B) and press OK.
Finally, the controller will ask you to replace the weigh hopper in the blender and press OK to complete the calibration.
The controller will verify that the calibration was done correctly by showing “Calibration Successful.”
Enter in the Calibration
Weight
Press here to perform the calibration
Go Back to the
Calibration Directory
Weigh Hopper (Load Cell) Calibration on blenders equipped with an HC style mixer
Enter the Setup menu as described previously. See Page 59 for menu tree. The factory
Button #3 on the Setup Menu is “Calibration”. Press it to enter the scale calibration menu.
1.Once in “Scale Calibration, enter in the scale calibration weight value stamped on the side of the weight.
2.Clean out the weigh hopper and press OK.
3.Place the calibration weight on top of the weigh hopper and press OK.
4.Remove the calibration weight when prompted.
5.The controller will verify that the calibration was done correctly by displaying “Calibration Successful.”
Note: It is imperative at this time that there is no mechanical binding of any kind on the weigh hopper. Adjust the load cell stops as described on page 35 .
Feeder Calibration (Auger Blenders)
Feeder calibration should be done on all Auger blenders prior to