Gravimetric Batch Blenders w/Mitsubishi Control Chapter 4: Operation 58
4-2 Controller Description & Operation
Display Description (LCD)
The Slide Gate/Auger blending system utilizes a standardized menu format. Each screen
was designed to be user-friendly and provide the operator with the necessary information to
run the blender.
A typical menu is shown in the figure above. This display, which is defaulted to when the
controller is turned on, provides the operator with the following information and options:
The ability to change Recipe Values
Accept a newly entered Recipe
Start or Stop the blender
Access to the Recipe Book
Access to the Clean-out Screen
Access to the Inventory Screen
Access to the Controller Setup Screen
Note: Please refer to the Slide Gate/Auger menu structure shown on the next page.
The menu tree shows the structure for a standard Slide Gate/Auger blender.
When the unit is initially installed the Manual Control menu will be used. This screen is
primarily used for trouble shooting the blender. All outputs can be controlled manually and
all digital inputs from the proximity switches can be viewed. Pressing the “Manual Control”
key when in the “Setup” menu accesses this screen. To gain access to the “Setup” menu, a
password will be requested.
Empty Entire
Blende
r
Test Alarm
Output
Current Hopper
Weight
Warning Message
Open or Close
Feede
r
Open or Close
Weigh Hopper
Start or Stop
Mixer Moto
r
Open or Close
Mixer Knife
Gate
Go back to
Setup Directory
Low Level
Prox Status