BEFORE CALLING FOR SERVICE

Symptom

Check & Remedy

Reference
page

 

 

 

 

 

No power

• Is the power cord plug disconnected from the outlet?

-

 

Connect the power cord plug to the outlet firmly.

 

 

 

 

The image is not printed.

• Is the image data sent to this unit?

7-10

 

Confirm that the image data is sent to this unit.

 

 

• Is the print paper or ink sheet used up?

12-15

 

Check the status.

 

 

• Is the printing unit set correctly?

15

 

Set the printing unit correctly.

 

 

 

 

The image stored in the memory can

• Is the image data of L-size transferred?

-

not be enlarged to the possible print

Check the status.

 

area.

• Is the large size ink sheet installed when transferring the image

-

 

data of L-size?

 

 

Set the ink sheet correctly.

 

 

 

 

The image can not be transferred.

• Is the ON LINE lamp lit?

5

 

Check the status.

 

 

 

 

COPY button does not work.

• Is the ON LINE lamp lit?

5

 

Press the ON LINE lamp to turn off the lamp.

 

 

 

 