CONNECTIONS

PARALLEL2DATA SIGNAL

Pin No.

 

Return pin No.

 

Signal

From/to

Function

 

 

 

 

 

 

 

 

1

19

 

 

STROBE

PC/DCP

Strobe pulse for data reading. Incoming pulse width should

 

 

 

 

 

 

 

 

 

 

be 0.5 ms minimum. At regular conditions, “High” data will be

 

 

 

 

 

 

 

 

 

 

read after becoming “Low”.

 

 

 

 

 

 

 

 

 

2

20

 

 

DATA1 (LSB)

PC/DCP

High:

data 1

3

21

 

 

DATA2

PC/DCP

Low:

data 0

4

22

 

 

DATA3

PC/DCP

Information will be expressed for parallel data of every signal

5

23

 

 

DATA4

PC/DCP

from bit No.1 to No.8.

6

24

 

 

DATA5

PC/DCP

 

 

 

7

25

 

 

DATA6

PC/DCP

 

 

 

8

26

 

 

DATA7

PC/DCP

 

 

 

9

27

 

 

DATA8 (MSB)

PC/DCP

 

 

 

 

 

 

 

 

 

 

 

 

 

10

28

 

 

 

 

 

 

DCP/PC

This signal is yielded after data input has ended by a data

 

 

ACK

 

 

 

 

 

 

 

(ACKNOWLEDGE)

 

reception acknowledgment pulse.

 

 

 

 

 

 

 

 

 

11

29

 

 

BUSY

DCP/PC

High:

DCP data is not accepted

 

 

 

 

 

 

 

 

 

 

Low:

DCP data is accepted

 

 

 

 

 

 

 

 

 

 

The signal becomes “High” in the following cases;

 

 

 

 

 

 

 

 

 

 

·

Off line status

 

 

 

 

 

 

 

 

 

 

·

During data entry

 

 

 

 

 

 

 

 

 

 

·

During printing

 

 

 

 

 

 

 

 

 

12

 

 

 

 

P·E

DCP/PC

High:

No paper

 

 

 

 

 

(PAPER END)

 

Low:

Paper available

 

 

 

 

 

 

 

 

 

13

 

 

 

 

SELECT

DCP/PC

High:

INPUT switch is PARALLEL and the ON LINE

 

 

 

 

 

 

 

 

 

 

 

button is pressed ON

 

 

 

 

 

 

 

 

 

 

Low:

Other than above

 

 

 

 

 

 

 

 

 

16,17

 

 

 

 

GND

 

Earth

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

DC5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19-30, 33

 

 

 

 

for twist pair return

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

DCP/PC

Low:

Abnormal condition occurs in DCP (e.g. error due to

 

FAULT

 

 

FAULT

 

 

 

 

 

 

 

 

 

 

 

paper jamming etc.)

 

 

 

 

 

 

 

 

 

14, 15, 34-36

 

 

 

 

NC

 

Unused

 

 

 

 

 

 

 

 

31

16

 

 

 

 

 

 

PC/DCP

Clears sending data. Incoming pulse width should be 100 ms

INT

 

 

 

 

 

 

(INITIALIZE)

 

minimum. At regular conditions, “High” data will be cleared

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

after becoming “Low”.

 

 

 

 

 

 

 

 

 

 

 

 

 

DCP : Digital Color Printer