5.2 Configuring the MELSEC Protocol

The database addresses in the ICC are used to address “byte” data locations. Thus, 248 words will take up 496 database addresses.

3.Select the “Monitor” tab and check the “Display Usage” checkbox to show the DB memory locations that are configured for use by both the Produced and Consumed data.

5.2 Configuring the MELSEC Protocol

The steps to properly configure the MELSEC Protocol in the ICC ETH-1000 are documented in this section. However, the user should realize that the steps here are examples for a particular configuration to establish the Verification System architecture as shown in Figure 2. For a particular application, the Connection Objects and Service Objects configured in this manual may not work properly without modifications. A user should consult the ICC ETH-1000 manual and understand the information required to be transfer to and from Mitsubishi controllers and the timing requirements.

The critical steps are the configuration of a MELSEC Connection Object and the services that need to be accomplished using this Connection Object. A Connection Object can be configured to represent a physical connection between an ICC ETH-1000 and a Mitsubishi controller. However, this does not have to be the case since a physical connection can support multiple “logical” connections using multiple connection objects depending on the application requirements.

After a Connection Object is configured, multiple Service Objects can be configured for this Connection Object. Each service object defines the tasks that need to be accomplished, for example read 20 words of controller D registers starting from D12287, write 10 words to controller Internal Relay.

5.2.1. Configuring Connection Objects

The following steps are used to create a Connection Object to communicate with a iQ PLC with the IP address 192.168.1.40 using TCP port 0x5001 (e.g. Decimal 20481)

1. Create a name for this Connection Object. The name is “Connection1” for this example.

5-3

 

1

 

 

 

 

 

 

 

 

 

Introduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

System Overview

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

Devices to the

Network

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

ControlLogix PLC Project

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

ETH-1000

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

Using EtherNet/IP

Explicit Messaging

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

Terminology

 

 

 

 

 

 

 

 

Page 27
Image 27
Mitsubishi Electronics ETH-1000 manual Configuring the MELSEC Protocol, Configuring Connection Objects