Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.

POWER indicator

STATUS indicator

POWER STATUS

Normal condition

POWER

STATUS

CONDITION

NOTE

 

 

 

 

 

 

 

 

 

 

 

Stand-by

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

Off

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp stand-by (about 1 minute)

The POWER button cannot be used to

Steady

Blinking

 

switch between on and off.

green

green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The power is on. (Normal condition)

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Steady

 

 

 

green

green

 

 

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

 

 

 

 

 

 

 

 

 

Abnormal temperature

 

 

 

 

 

 

 

 

 

 

 

Steady

 

 

 

 

 

 

 

• The ventilation grilles is clogged with dust or dirt.

• Clean the ventilation grilles.

green

 

 

 

 

 

 

 

• The room temperature is high.

• Relocate the projector to a cooler place.

or

Blinking orange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The protection circuit is working or the lamp is in an

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

abnormal condition.

Blinking green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Blinking green/red

lamp shutdown notice while the power is on. (See page 22.)

green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

Steady red

Blinking red

lamp shutdown notice while the power is off. (See page 22.)

Wait until the STATUS indicator goes out, then press the POWER button.

If the above solution is not effective, replace the lamp.

Replace the lamp.

Change with a new lamp if this problem recurs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

Steady red

lamp shutdown. (See page 22.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

 

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal.

Contact your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

 

Blinking

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

green/red

Blinking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN - 26

Page 26
Image 26
Mitsubishi Electronics EX100, ES100 user manual Indicators, Normal condition