FX2N-32DP-IF Profibus-DP Interface Units Appendix B
B-13
2) Step 2 of returning to default for FX2N-4AD
Table B-13:Step 2 of Returning to Default Settings for FX
2N
-4AD
Using GSD File User
Parame ter
Type Description
Using Programming Tool
Byte
No.
Setting
Valu e
(Hex)
Register
No.
Setting
Value
(Hex)
Higher/
Lower
Byte
0 00 H User
parameter
for 32DP -IF See sectio n 6.1. D200 0000 H Lower
1 00 H Higher
2DA H
User parameter
for special
function
block
(FX2N-4AD)
BFM #30 lower byte D201 07DA H Lower
3 07 H BFM #30 higher byte Higher
4 09 H Total length of parameter bytes for this
special function block are 9 bytes (byte
No. 4 ~ 12). D202 0409 H
Lower
5 04 H Example: number of BFM for data
exchanged every cycle is 4
BFMs (BFM #9 ~ #12). Higher
6 09 H Specified exchange, ex. BFM #9 D203 0A09 H Lower
7 0A H Spec ified exchange, ex. BFM #10 Higher
8 0B H Spec ified exchange, ex. BFM #11 D204 0C0B H Lower
9 0C H Specified exchange, ex. BFM #12 Higher
10 H94 Must be returned to “0000 H” in BFM
#20. D205 0094 H Lower
11 H00 BFM #21 lower byte: “00 H” Higher
12 H00 BFM #21 higher byte: “00 H” D206 0000 H Lower
- - - Higher