Troubleshooting

Before asking for repair of the projector, check the following. If the symptom persists, stop using the projector, be sure to unplug the power plug, and then contact your dealer.

No image appears on the screen.

Problem

Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power can not be

• Check whether the indicators are on or off and how they are lightning.

 

turned on.

POWER

STATUS

Solution

 

 

 

 

 

 

 

 

 

• Connect the power cord to the projector.

 

Off

 

Off

• Plug the power cord into a wall outlet.

 

 

 

 

 

 

 

 

 

• If any objects are blocking the air inlet or outlet grill, re move them and carry out the

 

 

 

 

 

 

 

 

following.

 

 

 

 

Off

1.

Unplug the power cord from the wall outlet.

 

 

 

 

2.

Make sure that the projector has cooled off.

 

 

 

 

 

 

 

 

3.

Plug the power cord into the wall outlet.

 

 

 

 

 

 

 

 

4.

Press the POWER button.

 

 

 

 

 

 

 

 

 

• If any objects are blocking the air inlet or outlet grille, remove them.

 

 

 

 

 

 

 

 

 

 

 

Blinking

• Don’t expose the air outlet grilles to hot air emitted from a heating appliance.

 

Steady red

orange

 

 

 

 

 

 

 

 

 

 

 

 

After the STATUS indicator stops blinking, press the POWER button.

 

 

 

 

 

If you unplug the power cord while the fan is rotating, the lamp may not turn on about one minute

 

 

 

 

 

 

 

 

 

 

Blinking

when you plug the power cord next time.

green

The lamp can’t turn on again for one minute after it goes out.

Press the POWER button several times.

 

 

 

 

 

 

 

 

 

 

• Replace the lamp. (The lamp is at the end of its life.)

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Attach the lamp cover.

 

 

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

• Unplug the power cord from the wall outlet and contact your dealer .

 

Blinking

Steady

 

 

 

or

 

red/green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No image appears on

• Check that the lens cap is removed.

the screen.

• It may take about one minute for the lamp to light up.

The lamp fails to light up on rare occasions. In such a case, wait for a few minutes and then try again.

If the projector was turned off before the lamp was cooled down sufficiently last time, the fan may start rotating and the POWER button may not work after the power cord is plugged. After the fan stops rotating, press the POWER button to turn back on the POWER indicator.

Check that the intake vent is clean.

Set SCART INPUT in the FEATURE menu to OFF. (See page 28.)

Check that the lamp cover is closed. (See page 37.)

Check that the cables connected to the external devices are not broken.

When an extension cable is being used, replace it with the supplied cable for check. When images are displayed correctly, add an RGB signal amplifier to the extension cable.

Check the operation manual of the video device for its connection.

Power turns off.

• This problem may occur when the intake vent and/or exhaust vents are blocked. (In

 

such a case, the STATUS indicator brinks orange.)

 

Remove the objects blocking the intake vent and/or exhaust vents and then carry

 

 

out the following procedure.

 

1.

Wait for the intake fan and/or exhaust fan to stop. (Wait until the STATUS indicator

 

 

goes out.)

 

. Unplug the power cord from the wall outlet.

 

. Wait at least 10 minutes.

 

4.

Plug the power cord into the wall outlet.

 

5.

Press the POWER button.

 

• When the STATUS indicator is steady red, it is indicating that the lamp should be

 

replaced. Replace the lamp in this case.

 

• Check that AUTO POWER OFF has been set to OFF.

 

• If the lamp has deteriorated, it may go out after a while it illuminates.

EN-40

Page 40
Image 40
Mitsubishi Electronics HC3800 user manual Troubleshooting, No image appears on the screen Problem Solution

HC3800, HC3800 specifications

The Mitsumi Electronic HC3800 is a versatile and innovative device that plays a crucial role in enhancing connectivity and signal transmission in various electronic applications. Designed to meet the demands of modern technology, the HC3800 stands out due to its robust features, cutting-edge technology, and reliable performance.

One of the main features of the HC3800 is its high-speed data transmission capabilities. It supports advanced protocols that allow for quick and efficient communication between devices. This is particularly important in applications such as telecommunications, automotive systems, and industrial automation where speed and reliability are paramount. The HC3800 ensures minimal latency, enabling real-time data processing and response.

Another highlight of the HC3800 is its compact and efficient design. With a small footprint, it can easily be integrated into a wide range of devices, from handheld gadgets to larger industrial equipment. This versatility makes it a preferred choice for manufacturers looking to optimize space without compromising on performance.

The HC3800 employs advanced modulation techniques, which enhance signal integrity and reduce interference. This is critical in environments where electromagnetic interference (EMI) can disrupt communications. By utilizing robust error detection and correction algorithms, the HC3800 maintains high levels of data integrity, ensuring that information is transmitted accurately even in challenging conditions.

Moreover, the Mitsumi HC3800 boasts an impressive power efficiency profile. It is engineered to operate effectively at lower power levels, making it suitable for battery-operated devices. This not only extends the longevity of devices using the HC3800 but also complies with green technology initiatives aimed at reducing energy consumption.

The technology within the HC3800 is continually evolving, ensuring compatibility with future advancements. Mitsumi's commitment to research and development means that users can expect regular updates and improvements in performance features. Additionally, the HC3800 provides extensive support for a wide array of interfaces, making it adaptable to various system architectures.

In conclusion, the Mitsumi Electronic HC3800 is a state-of-the-art component that combines high-speed data transmission, compact design, superior signal integrity, and energy efficiency. Its features make it an ideal choice for a multitude of applications across different industries, ensuring that users benefit from enhanced connectivity and reliable performance in their electronic systems. Whether it's for personal or industrial use, the HC3800 continues to meet and exceed market demands while shaping the future of electronic connectivity.