Mitsubishi Electronics LVP-SA51U user manual User memory for signal setting

Models: LVP-SA51U

1 31
Download 31 pages 58.98 Kb
Page 17
Image 17
User memory for signal setting

4SIGNAL

MEMORY CALL ........ Use to select AUTO, USER 1 or USER 2. See below.

 

 

 

 

 

Opt

 

 

 

 

 

 

XGA60

HORIZ. POSITION .... Use to adjust the horizontal position of the image.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERT. POSITION ..... Use to adjust the vertical position of the image.

 

SIGNAL

 

 

 

 

 

FINE SYNC. ....... Use to synchronize the projector with PC input signals so

 

 

A

MEMORY CALL

 

 

 

AUTO

 

 

U

 

 

 

 

 

 

 

 

 

 

 

 

that the image is not blurred.

 

 

 

HORIZ. POSITION

 

0

 

 

TRACKING ......... Use to avoid image noise such as wide stripes.

 

 

 

VERT. POSITION

 

0

 

 

 

 

 

 

 

 

 

 

 

FINE SYNC.

 

0

 

 

COMPUTER INPUT .... The unit adjusts itself automatically when connected to a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRACKING

 

0

 

 

DVD player with component video output (Y, CB, CR) or

 

 

 

 

 

 

 

 

 

COMPUTER INPUT

 

 

 

RGB

equipment with HDTV SIGNAL output (Y, PB, PR). In the

 

 

RRGGBB

 

 

 

 

 

 

HOLD

 

 

 

AUTO

case the projector is connected to equipment that includes

 

 

 

 

 

 

 

 

USER MEMORIZE

DELETE DEFAULT

RGB output terminal, adjust to RGB mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOLD .................. Adjusts the image when flagging occurs near the top of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 SIGNAL - USER (Normally, there is no need for adjustments.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLAMP POSITION/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLAMP WIDTH ......... If you use something similar, the brighter colors of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL-USER

 

 

 

 

 

projected image may become blurred. In this case, adjust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLAMP POSITION

 

0

 

 

CLAMP POSITION or CLAMP WIDTH.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLAMP WIDTH

 

0

 

 

HORIZ.PIXELS .. Use to adjust the width of the image. The image size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZ. PIXELS

 

0

 

 

grows wider as the number increases. (Adjust to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERT. LINES

 

0

 

 

horizontal pixels of the input signal for normal setting.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLL

 

 

 

AUTO

VERT.LINES ...... Use to adjust the height of the image. The image size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

?

VERT. SYNC.

 

 

 

AUTO

grows higher as the number increases. (Adjust to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER(U)

 

0

 

 

vertical lines of the input signal for normal setting.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER(L)

 

0

 

 

PLL ...................... Use to adjust the image when skewed on top. Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER(LS)

 

0

 

 

AUTO for normal setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER(RS)

0

 

 

VERT.SYNC. ...... Use to adjust the image when its motion does not run

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

smoothly. Select AUTO for normal setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER(U) ..... Use to adjust the image when the noise etc. appears on top part of image.

SHUTTER(L) ...... Use to adjust the image when the noise etc. appears on bottom part of image.

SHUTTER(LS) .... Use to adjust the image when the noise etc. appears on left side of image.

SHUTTER(RS) ... Use to adjust the image when the noise etc. appears on right side of image.

User memory for signal setting

This projector can memorize the maximum of 2 signal menu settings.

Memorizing the setting

1.Select MEMORIZE in the SIGNAL menu, and press the ENTER button.

2.Press the $ or % button to select the memory which you wish to record (USER 1 or USER 2).

3.Press the ENTER button.

Initialite the setting which has been changed (Default)

Select RESET in the SIGNAL menu, and press the ENTER button.

When initializing, selection buttons will not work for about 2 - 18 seconds.

Select the user setting

Select MEMORY CALL in SIGNAL menu, and press the $ or % button to select the memory (USER 1 or USER 2).

Reset the recorded setting

1.Select DELETE in the SIGNAL menu, and press the ENTER button.

2.Press the $ or % button to select the memory which you wish to reset (USER 1 or USER 2).

3.Press the ENTER button.

The recorded setting will be reset.

ENGLISH

EN – 17

Page 17
Image 17
Mitsubishi Electronics LVP-SA51U user manual User memory for signal setting