3)Control sequence

(1)The command from a personal computer to the projector will be sent in 400ms.

(2)The projector will send a return command 400ms* after it has received an encode. If the command isn’t received correctly, the projector will not send the return command.

(3)The personal computer checks the command and confirms if the command which has been sent has been executed or not.

(4)This projector sends various codes other than the return code. When having a control sequence by RS- 232C, reject other codes from personal computer side.

* : The sending time of return command may delay depending on the condition (during changing the input signal, etc.).

[Example] Turn the power ON (' 'is for ASCII code)

Sending commands

 

Status code from

Meaning

from the PC etc.

 

projector

 

30 30 21 0D

 

 

Command for POWER ON

'0' '0' '!' ' '

 

 

 

 

 

 

 

30 30 21 0D

Command received

 

'0'

'0' '!' ' '

(Command echo back)

4) Operation commands

The operation commands execute the basic operation setting of this projector. It may not operate when chang- ing the signal.

Operation

ASCII

HEX

 

 

POWER ON

!

21h

 

 

POWER OFF

"

22h

 

 

INPUT COMPUTER 1

_r1

5Fh

72h

31h

INPUT COMPUTER 2

_r2

5Fh

72h

32h

INPUT VIDEO 1

_v1

5Fh

76h

31h

INPUT VIDEO 2

_v2

5Fh

76h

32h

POWER OFF command will not work for 1 minute after the power is turned on.

POWER ON command will not work for 1 minute after the power is turned off.

[Example] Set the input signal to COMPUTER 1 (' 'is for ASCII code)

Sending commands

Status code from

Meaning

from the PC etc.

projector

 

30 30 5F 72 31 0D

 

Command for setting the input

'0' '0' '_' 'r' '1' ' '

 

signal to COMPUTER 1

 

 

 

 

30 30 5F 72 31 0D

Command received

 

'0' '0' '_' 'r' '1' ' '

(Command echo back)

 

 

 

5) Remote commands

Some remote control operations can be done by remote command codes.

Button's name on remote

ASCII

HEX

 

 

 

 

 

+ VOLUME

r06

72h

30h

36h

 

 

 

– VOLUME

r07

72h

30h

37h

 

 

 

MUTE

ra6

72h

61h

36h

 

 

 

 

EXPAND

r02

72h

30h

32h

 

 

APPENDIX

PinP

r04

72h

30h

34h

 

 

 

 

{

r53

72h

35h

33h

 

 

 

}

r2b

72h

32h

62h

 

 

 

$

r4f

72h

34h

66h

 

 

 

%

r59

72h

35h

39h

 

 

 

MENU

r54

72h

35h

34h

 

 

 

ENTER

r10

72h

31h

30h

 

 

 

ZOOM/FOCUS

r0f

72h

33h

66h

 

 

 

AUTO POSITION

r09

72h

30h

39h

 

 

 

STILL

ra4

72h

61h

34h

 

 

 

AP – 3

Page 30
Image 30