WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

1Set to the highest temperature in manual COOL mode,

and operate for 3 to 4 hours. Page 4

This dries the inside of the unit.

2Press to stop the operation.

3Turn off the breaker and/or disconnect the power sup- ply plug.

4Remove all batteries from the remote controller.

When using the air conditioner again:

1Clean the air fi lter. Page 6

2Check that the air inlet and outlet of the indoor and outdoor units are not blocked.

3Check that the earth is connected correctly.

INSTALLATION PLACE AND ELECTRICAL WORK

Installation place

Avoid installing the air conditioner in the following places.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfi de gas is generated such as a hot spring.

Where oil is splashed or where the area is fi lled with oily smoke.

Where there is high-frequency or wireless equipment.

Where the air from the outdoor unit air outlet is blocked.

Where the operation sound or air from the outdoor unit does not bother the house next door.

 

 

 

 

The installation location of the outdoor unit should

 

 

 

 

be at least 3 m away from the antennas for TV sets,

 

 

 

 

radios, etc. In areas where the reception is weak,

 

 

 

 

provide greater space between the outdoor unit and

 

 

 

 

the antenna of the affected device if operation of the air

 

 

 

 

conditioner interferes with radio or TV reception.

 

 

Inverter-type

 

 

 

To prevent the effects

fl uorescent lamp

 

 

 

 

 

 

 

of a fl uorescent lamp,

 

 

 

wall, etc.

keep as far apart as

 

 

 

 

 

 

 

possible.

 

 

 

 

Well-

 

 

 

 

 

 

 

 

 

 

ventilated dry

 

 

Keep a space to

place

 

 

 

 

 

prevent the pic-

 

 

 

ture distortion or

100 mm or

1 m

 

the noise.

 

 

more

 

 

 

 

200/500 mm

or more

 

TV

 

 

 

1 m

 

 

or more

Cordless

or more

 

 

 

 

 

 

 

 

phone or

 

 

 

 

 

Portable

 

 

3 m or

 

phone

Radio

 

SD13/D18, D24

 

 

more

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

SPECIFICATIONS

Model

 

MCF-SD13VD

MCF-D18VD

MCF-D24VD

Dimensions

Indoor

650 × 1100 × 180

650 × 1100 × 180

650 × 1100 × 180

H × W × D (mm)

Outdoor

550 × 800 × 285

850 × 840 × 330

850 × 840 × 330

Weight (kg)

Indoor

26

26

26

Outdoor

34

54

65

 

Note:

1.Rating condition

Cooling — Indoor: 27°C DB, 19°C WB Outdoor: 35°C DB, 24°C WB

2.Guaranteed operating range

 

Indoor

Outdoor

 

Upper limit

32°C DB

43°C DB

 

23°C WB

 

 

 

Lower limit

21°C DB

21°C DB

 

15°C WB

 

 

 

 

 

 

 

Environment care

Mitsubishi Electric Air conditioner has been designed environment-friendly. The plastic composition can be used as recycle part. For the optimum effi ciency and energy saving, users are recommended to operate air conditioners as following suggestion.

Turn off air conditioner in case of not in use.

Turn off ventilator in case of not in use.

The set temperature should not be set lower than 25°C.

The cleaning of condensing coil should be performed at least every 3 months.

The cleaning of air cleaning fi lter should be performed in the period described in this manual.

En-8

Page 9
Image 9
Mitsubishi Electronics MCF-D18VD, MCF-D24VD Installation Place and Electrical Work, Specifications, Installation place