Mitsubishi Electronics MSZ-GA24NA When You Think That Trouble Has Occurred, En-9, Symptom, Page

Models: MSZ-GA24NA

1 32
Download 32 pages 21.96 Kb
Page 10
Image 10
WHEN YOU THINK THAT TROUBLE HAS OCCURRED

● OPERATING INSTRUCTIONS ●

WHEN YOU THINK THAT TROUBLE HAS OCCURRED

Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

 

 

 

 

 

The unit cannot be operated.

• Is the breaker turned on?

 

• Is the power supply plug connected?

 

• Is the ON timer set?

Page 7

 

 

 

 

 

 

 

 

 

The unit cannot be operated

• This protects the unit according to instruc-

for about 3 minutes when

tions from the microprocessor. Please

restarted.

wait.

Mist is discharged from the air

• The cool air from the unit rapidly cools mois-

outlet of the indoor unit.

ture in the air inside the room, and it turns

 

into mist.

The swing operation of the

• This is for the swing operation of the HORI-

HORIZONTAL / VERTICAL

ZONTAL / VERTICAL VANE to be performed

VANE is suspended for a

normally.

while, then restarted.

 

 

 

 

 

The air fl ow direction changes

• When the unit is operated in COOL or DRY

during operation.

mode, if the operation continues with air

The direction of the horizontal

blowing down for 0.5 to 1 hour, the direction

vane cannot be adjusted with

of the air fl ow is automatically set to horizon-

the remote controller.

tal position to prevent water from condensing

 

and dripping.

 

• In the heating operation, if the air fl ow tem-

 

perature is too low or when defrosting is be-

 

ing done, the horizontal vane is automatically

 

set to horizontal position.

The operation is stopped for

• Defrosting of the outdoor unit is being

about 10 minutes in the heat-

done.

ing operation.

Since this is completed in max.10 minutes,

 

please wait. (When the outside temperature

 

is too low and humidity is too high, frost is

 

formed.)

The unit starts operation by

• These models are equipped with an auto re-

itself when the main power

start function. When the main power is turned

is turned on, though it isn’t

off without stopping the unit with the remote

operated with the remote

controller and is turned on again, the unit

controller.

starts operation automatically in the same

 

mode as the one set with the remote control-

 

ler just before the shutoff of the main power.

 

Refer to “Auto restart function”

Page 5

.

 

 

 

 

 

 

Multi system

 

 

 

 

 

The indoor unit which is not

• A small amount of refrigerant continues to

operating becomes warm and

fl ow into the indoor unit even though it is not

a sound, similar to water fl ow-

operating.

ing, is heard from the unit.

 

 

 

 

 

When heating operation is

• When operation is started during defrosting

selected, operation does not

of outdoor unit is done, it takes a few minutes

start right away.

(max. 10 minutes) to blow out warm air.

Outdoor Unit

 

 

 

 

 

The fan of the outdoor unit

• When the outside temperature is low dur-

does not rotate even though

ing cooling operation, the fan operates

the compressor is running.

intermittently to maintain suffi cient cooling

Even if the fan starts to rotate,

capacity.

it stops soon.

 

 

 

 

 

Water leaks from the outdoor

• During COOL and DRY operations, pipe or

unit.

pipe connecting sections are cooled and this

 

causes water to condense.

 

• In the heating operation, water condensed

 

on the heat exchanger drips down.

 

• In the heating operation, the defrosting op-

 

eration makes water frozen on the outdoor

 

unit melt and drip down.

White smoke is discharged

• In the heating operation, vapor generated

from the outdoor unit.

by the defrosting operation looks like white

 

smoke.

Symptom

 

Explanation & Check points

Remote controller

 

 

 

 

 

 

 

 

 

The display on the remote

• Are the batteries exhausted?

Page 4

 

 

controller does not appear

• Is the polarity (+, -) of the

batteries

correct?

or it is dim. The indoor unit

 

Page 4

 

 

 

 

 

does not respond to the

Are any

buttons on the remote controller of

remote control signal.

other electric appliances being pressed?

Does not cool or heat

 

 

 

 

 

 

 

 

 

The room cannot be cooled

• Is the temperature setting appropriate?

or heated suffi ciently.

Page 5

 

 

 

 

 

 

Is the fan setting appropriate? Please

 

change fan speed to higher setting.

Page 6

 

 

• Are the fi lters clean?

Page 8

the indoor unit

 

• Is the fan or heat exchanger of

 

clean?

 

• Are there any obstacles blocking the air inlet

 

or outlet of the indoor or outdoor unit?

 

• Is a window or door open?

The room cannot be cooled

• When a ventilation fan or a gas cooker is

suffi ciently.

used in a room, the cooling load increases,

 

resulting in an insuffi cient cooling effect.

 

• When the outside temperature is high, the

 

cooling effect may not be suffi cient.

The room cannot be heated

• When the outside temperature is low, the

suffi ciently.

heating effect may not be suffi cient.

Air does not blow out soon in

• Please wait as the unit is preparing to blow

the heating operation.

out warm air.

Airflow

 

 

 

 

 

 

 

 

 

The air from the indoor unit

• Are the fi lters clean?

Page 8

 

smells strange.

• Is the fan or heat exchanger of

the indoor unit

 

clean?

 

• The unit may suck in an odor adhering to the

 

wall, carpet, furniture, cloth, etc. and blow it

 

out with the air.

Sound

 

 

 

 

 

 

 

 

 

Cracking sound is heard.

• This sound is generated by the expansion/

 

contraction of the front panel, etc. due to

 

change in temperature.

“Burbling” sound is heard.

• This sound is heard when the outside air is

 

absorbed from the drain hose by turning on

 

the range hood or the ventilation fan, making

 

water fl owing in the drain hose to spout out.

 

This sound is also heard when the outside air

 

blows into the drain hose in case the outside

 

wind is strong.

Mechanical sound is heard

• This is the switching sound in turning on/off

from the indoor unit.

the fan or the compressor.

The sound of water fl owing

• This is the sound of refrigerant or condensed

is heard.

water fl owing in the unit.

Hissing sound is sometimes

• This is the sound when the fl ow of refrigerant

heard.

inside the unit is switched.

In the following cases, stop using the air conditioner and consult your dealer.

When water leaks or drips from the indoor unit.

When the left operation indicator lamp blinks.

When the breaker trips frequently.

The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

Operation of the air conditioner interferes with radio or TV reception. An ampli- fi er may be required for the affected device.

When an abnormal sound is heard.

En-9

Page 10
Image 10
Mitsubishi Electronics MSZ-GA24NA When You Think That Trouble Has Occurred, En-9, Operating Instructions, Symptom, Page