● OPERATING INSTRUCTIONS ●
SELECTING OPERATION MODES
1 | Press | to start the operation. |
2 | Press | to select operation mode. Each press |
| changes mode in the following order: | |
|
| (AUTO) |
|
| (COOL) |
AUTO mode (Auto change over)
The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is 4°F (2°C) away from the set temperature for more than 15 minutes.
Note:
•During multi system operation, the unit may not be able to switch opera- tion mode between COOL and HEAT. In this case, the indoor unit becomes standby mode.
•Auto Mode is not recommended if this indoor unit is connected to a MXZ type outdoor unit.
COOL mode
Enjoy cool air at your desired temperature.
Do not operate COOL mode at very low outside temperatures. (less than 14°F
Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
HEAT mode
Enjoy warm air at your desired temperature.
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation switch (E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation changes in the following order:
|
| (DRY) |
|
| (HEAT) |
3 Press | or | to set the temperature. |
Each press raises or lowers the temperature by 1°F | ||
(1°C). |
|
|
Press | to stop the operation. |
Operation indicator lamp
Emergency COOL
Emergency HEAT
Stop
Note:
Set temperature : 75°F (24°C)
Fan speed : Medium
Horizontal vane : Auto
• The same setting is selected the next time by simply pressing | . |
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication | Operation state |
| Room temperature |
The unit is operating to reach the set | About 4°F (2°C) or | ||
more away from set | |||
temperature |
| temperature | |
|
|
| |
The room temperature is approach- | About 2 to 4°F (1 to | ||
2°C) from set tem- | |||
ing the set temperature |
| perature | |
|
|
| |
Standby mode (only during multi | — | ||
system operation) |
| ||
|
| ||
Lighted | Blinking | Not lighted |
The fi rst 30 minutes of operation is test run. Temperature control does not work, and fan speed is set to High.
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service repre- sentative because the setting of the unit needs to be changed.
Multi system operation
Two or more indoor units can be operated by one outdoor unit. When several indoor units are operated simultaneously, cooling and heating operations cannot be done at the same time. When COOL is selected with one unit and HEAT with another or vice versa, the unit operated later becomes standby mode.