WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME

1 Set to the highest temperature in manual COOL mode, and operate for 3 to 4 hours. Page 5

This dries the inside of the unit.

Moisture in the air conditioner contributes to favorable conditions for growth of fungi, such as mold.

2

Press

to stop the operation.

3

Turn off the breaker and/or disconnect the power sup-

 

ply plug.

 

INSTALLATION PLACE AND ELECTRICAL WORK

Installation place

Avoid installing the air conditioner in the following places.

Where there is much machine oil.

Salty places such as the seaside.

Where sulfi de gas is generated such as a hot spring.

Where oil is splashed or where the area is fi lled with oily smoke.

Where there is high-frequency or wireless equipment.

Where the air from the outdoor unit air outlet is blocked.

Where the operation sound or air from the outdoor unit does not bother the house next door.

The installation location of the outdoor unit should be at least 10ft (3 m) away from the antennas for TV sets, radios, etc. In areas where the reception is weak, provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception.

4 Remove all batteries from the remote controller.

When using the air conditioner again:

1

Clean the air fi lters.

 

 

Page 8

 

 

 

 

2

 

 

 

To prevent the effects of a fl uorescent lamp, keep as far apart as possible.

3ft

(1m)

or more

3 ft (1m)

 

or more

Cordless phone or Portable

Inverter-type

fl uorescent lamp

Keep a space to prevent the pic- ture distortion or the noise.

TV

wall, etc.

Well- ventilated dry place

4 in (100 mm)

or more 20 in

(500 mm) or more

Check that the air inlet and outlet of the indoor and

outdoor units are not blocked.

phone

Radio

10 ft (3 m) or more

3 Check that the ground wire is connected correctly.

SPECIFICATIONS

Guaranteed operating range

 

 

Indoor

Outdoor

 

Upper limit

90°F (32.2°C) DB

115°F (46.1°C) DB

Cooling

73°F (22.8°C) WB

Lower limit

67°F (19.4°C) DB

14°F (-10°C) DB

 

 

57°F (13.9°C) WB

 

 

 

Upper limit

80°F (26.7°C) DB

75°F (23.9°C) DB

 

65°F (18.3°C) WB

 

 

Heating

Lower limit

70°F (21.1°C) DB

5°F (-15°C) DB

(USA model)

4°F (-15.6°C) WB

 

Lower limit

70°F (21.1°C) DB

14°F (-10°C) DB

 

(Canada model)

13°F (-10.6°C) WB

 

 

 

DB : Dry Bulb

 

 

 

WB : Wet Bulb

Electrical work

Provide an exclusive circuit for the power supply of the air conditioner.

Be sure to observe the breaker capacity.

If you have any questions, consult your dealer.

En-10
Page 11