![](/images/new-backgrounds/1014517/1451719x1.webp)
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Model | Refrigerant piping : ft. |
| Piping size O.D : in. | ||
Max. Length | Max. Height difference | Gas |
| Liquid | |
| A | B |
| ||
|
|
|
| ||
|
|
|
|
| |
100 | 50 | 5/8 |
| 3/8 | |
| |||||
|
|
|
|
| |
|
|
|
|
|
Indoor unit
Max. Height
difference
B
Max. length
A
Outdoor unit
ADDITIONAL REFRIGERANT CHARGE (R410A:oz.)
Refrigerant piping exceeding 25 ft. requires additional refrigerant charge according to the calculation.
Model | Outdoor unit |
|
|
| Refrigerant piping length (one way) : ft. |
|
| ||||
precharged | 25 | 30 |
| 40 | 50 | 60 | 70 | 80 | 90 | 100 | |
|
| ||||||||||
4 lb. 10 oz. | 0 | 2.96 |
| 8.88 | 14.80 | 20.72 | 26.64 | 32.56 | 38.48 | 44.40 | |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Calculation : X oz. = 2.96/5 oz. / ft. x (Refrigerant piping length (ft.) - 25) | |||||||
Model | Outdoor unit |
|
|
| Refrigerant piping length (one way) : ft. |
|
| ||||
precharged | 25 | 30 |
| 40 | 50 | 60 | 70 | 80 | 90 | 100 | |
|
| ||||||||||
4 lb. | 0 | 1.08 |
| 3.24 | 5.40 | 7.56 | 9.72 | 11.88 | 14.04 | 16.20 | |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Calculation : X oz. = 1.08/5 oz. / ft. x (Refrigerant piping length (ft.) - 25)
NOTE : Refrigerant piping exceeding 25 ft. requires additional refrigerant charge according to the calculation.
10