SAFETY PRECAUTION

3-1. ALWAYS OBSERVE FOR SAFETY

Before obtaining access to terminals, all supply circuits must be disconnected.

3-2. CAUTIONS RELATED TO NEW REFRIGERANT

Cautions for units utilising refrigerant R410A

Use new refrigerant pipes.

Make sure that the inside and outside of refrige- rant piping is clean and it has no contamination such as sulfur hazardous for use, oxides, dirt, shaving particles, etc.

In addition, use pipes with specified thickness.

Contamination inside refrigerant piping can cause deterio- ration of refrigerant oil etc.

Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing. (Leave elbow joints, etc. in their packaging.)

If dirt, dust or moisture enters into refrigerant cycle, that can cause deterioration of refrigerant oil or malfunction of com- pressor.

Use ester oil, ether oil or alkylbenzene oil (small amount) as the refrigerant oil applied to flares and flange connections.

If large amount of mineral oil enters, that can cause deterio- ration of refrigerant oil etc.

Do not use refrigerant other than R410A.

If other refrigerant (R22 etc.) is used, chlorine in refrige- rant can cause deterioration of refrigerant oil etc.

Use a vacuum pump with a reverse flow check valve.

Vacuum pump oil may flow back into refrigerant cycle and that can cause deterioration of refrigerant oil etc.

Use the following tools specifically designed for use with R410A refrigerant.

The following tools are necessary to use R410A refrigerant.

 

Tools for R410A

Gauge manifold

 

Flare tool

Charge hose

 

Size adjustment gauge

Gas leak detector

 

Vacuum pump adaptor

Torque wrench

 

Electronic refrigerant

 

 

charging scale

 

 

 

Keep the tools with care.

If dirt, dust or moisture enters into refrigerant cycle, that can cause deterioration of the refrigerant oil or malfunction of the compressor.

Charge refrigerant from liquid phase of gas cylinder.

If the refrigerant is charged from gas phase, composition change may occur in refrigerant and the efficiency will be lowered.

Do not use a charging cylinder.

If a charging cylinder is used, the composition of refrigera- nt will change and the efficiency will be lowered.

Ventilate the room if refrigerant leaks during operation. If refrigerant comes into contact with a flame, poisonous gases will be released.

[1]Cautions for service

(1)Perform service after collecting the refrigerant left in a unit completely.

(2)Do not release refrigerant in the air.

(3)After completing service, charge the cycle with specified amount of refrigerant.

(4)When performing service, install a filter drier simultaneously. Be sure to use a filter drier for new refrigerant.

3

Page 3
Image 3
Mitsubishi Electronics PCA-A24GA service manual Safety Precaution, Always Observe for Safety

PCA-A24GA specifications

Mitsubishi Electronics has long been a pioneer in the field of industrial automation, and the PCA-A24GA is a notable addition to its line of high-performance programmable controllers. This compact yet powerful device is designed to optimize processes and increase efficiency across various applications, making it a preferred choice for industries ranging from manufacturing to building automation.

One of the standout features of the PCA-A24GA is its versatility. The controller offers a wide range of input/output (I/O) options, enabling seamless integration with various sensors and actuators. With 24 digital input channels and 16 relay output channels, the PCA-A24GA can handle complex control tasks while maintaining a compact footprint. This flexibility is further enhanced by its support for analog inputs and outputs, allowing for greater precision in monitoring and controlling processes.

The PCA-A24GA is built with cutting-edge technologies that ensure robust performance. It employs Mitsubishi's advanced processing algorithms, which enhance real-time data processing capabilities. This ensures responsive control, reducing lag and improving overall system performance. Additionally, the controller features an intuitive programming environment, making it accessible to both seasoned engineers and those new to automation programming.

Communications are another strong suit of the PCA-A24GA. It offers multiple communication protocols, including Ethernet and RS-232, which allow for easy connectivity to various devices and systems. This ensures that the PCA-A24GA can be integrated into existing networks without significant modifications, facilitating smoother transitions and upgrades.

In terms of reliability and durability, the PCA-A24GA excels. Designed to operate in demanding environments, it is built to withstand temperature fluctuations, vibrations, and dust, which is essential for industrial settings. The controller's long operational life reduces maintenance costs and downtime, contributing to improved productivity.

Energy efficiency is also a key characteristic of the PCA-A24GA. Mitsubishi Electronics has designed this controller with eco-friendly technologies, making it suitable for organizations looking to reduce their carbon footprint while maintaining high levels of productivity.

In summary, the Mitsubishi Electronics PCA-A24GA stands out with its versatile I/O options, advanced processing capabilities, comprehensive communication protocols, and robust build. These features make it an excellent choice for industries seeking reliable and efficient automation solutions, securing Mitsubishi's reputation as a leader in the field.