[Legend]
Symbol |
| Name | Symbol |
| Name | Symbol |
| Name | |||
I.B | Indoor controller board |
| X1 | Aux.relay | Drain pump | TH21 | Thermistor | Room temp. detection | |||
| CN25 | Connector | Humidifier |
| T | Transformer |
|
|
|
| (32°F/15k", 77°F/5.4k") |
| CN27 |
| Damper |
| LED1 | Power supply (I.B) | TH22 |
| Pipe temp. detection / Liquid | ||
| CN32 |
| Remote switch |
| LED2 | Power supply (I.B) |
|
|
| (32°F/15k", 77°F/5.4k") | |
| CN51 |
| Centrally control | MF | Fan motor (with inner thermo) | TH23 |
| Pipe temp. detection / Gas | |||
| CN52 |
| Remote Indication | MV | Vane motor |
|
|
|
| (32°F1/15k", 77°F/5.4k") | |
| SW2 | Switch | Capacity code | DP | Drain water | A.B | Address board |
| |||
| SW3 |
| Mode selection | DS | Drain sensor |
|
| SW1 | Switch | Mode selection | |
| SW4 |
| Model selection | LEV | Linear expansion valve |
| SW5 |
| Voltage selection | ||
| ZNR | Varistor |
| TB2 | Terminal | Power supply |
| SW11 |
| Address setting 1st digit | |
| FUSE | Fuse (6A / 250V) | TB5 | block | Transmission |
| SW12 |
| Address setting 2nd digit | ||
|
|
|
| TB15 |
|
| SW14 |
| Connection No. |
Note
1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2.In case of using
4.Symbol [S] of TB5 is the shield wire connection.
5.Symbols used in wiring diagram above are, : terminal block, :connecter.
6.The setting of the SW2, SW3 dip switches differs in the capacity for the detail, refer to the fig : w1. 7.Please set the switch SW5 according to the power supply voltage.
LED on indoor board for service
Mark | Meaning | Function | |
LED1 | Main power supply | Main power supply (Indoor | |
Power on ➝ Lamp is lit. | |||
|
| ||
LED2 | Power supply for | Power supply for | |
on ➝ Lamp is lit. |
<fig : w1>
Models |
| SW2 |
|
| SW3 | |||
P06 | ON |
|
|
| ON |
|
|
|
OFF |
|
|
| OFF |
|
|
| |
| 1 2 3 4 5 6 |
| 1 2 3 4 5 6 7 8 910 | |||||
P08 | ON |
|
|
| ON |
|
|
|
OFF |
|
|
| OFF |
|
|
| |
| 1 2 3 4 5 6 |
| 1 2 3 4 5 6 7 8 910 | |||||
P12 | ON |
|
|
| ON |
|
|
|
OFF |
|
|
| OFF |
|
|
| |
| 1 2 3 4 5 6 |
| 1 2 3 4 5 6 7 8 910 | |||||
P15 | ON |
|
|
| ON |
|
|
|
OFF |
|
|
| OFF |
|
|
| |
| 1 2 3 4 5 6 |
| 1 2 3 4 5 6 7 8 910 |
(w2)Use copper supply wire.
PMFY-P06NBMU-E PMFY-P08NBMU-E
6 WIRING DIAGRAM
10
TO | TB15 |
1 |
CONTROLLER 2
ORN
ORN
|
| DS |
I.B |
| |
|
| 3 2 1 |
1 |
| (WHT) |
CN3A | DRAIN | |
2 | (BLU) | CN31 |
3 |
|
|
TH23 | TH22 | TH21 | LEV |
|
|
|
| BLU BRN ORN YLW RED | WHT |
|
|
| 6 |
|
2 1 | 2 1 | 2 1 | 6 5 4 3 2 1 | |
(BLK) | (WHT) | (RED) | (WHT) |
|
GAS | LIQUID INTAKE | LEV |
| |
CN29 | CN21 | CN20 | CN60 |
|
MV
1 2 3 4 5
BRN RED ORN YLW GRN
6 5 4 3 2 1
(GRN)
VANE CN6V
2 1 2 1
CN25 CN27
8 |
7 |
PMFY-P12NBMU
5 | 1 | 5 | 1 |
(WHT) (GRN)
(RED) | 6 | |
5 | ||
ADDRESS |
8
-
TO OUTDOOR UNIT | S(SHIELD) | TB5 | LED2 |
|
| ||
|
|
|
BC CONTROLLER | M2 | BLU | 1 | (BLU) |
REMOTE CONTROLLER | M1 | BLU | ||
|
| 2 | CN2M | |
|
|
|
|
CENTRALLY REMOTE
CONTROL INDICATION
CN51 CN52
1 2 |
8 910 |
CN81 | 4 |
| 3 |
| 2 |
| 1 |
| 4 |
A.B
8 7 6 5 4 3 2 1
(RED)
E PMFY
POWER SUPPLY | 5 | |
MF | ||
~ / N |
6 |
|
5 |
|
4 | FAN |
3 | (WHT) |
T
X1
SW3 | 45 6 7 |
| 1 2 3 |
(RED) | 3 |
ADDRESS | 2 |
CN42 | 1 |
|
4
4 3 2 1
(RED)
ADDRESS
ADDRESS
CN82
SW14 | 0 |
|
CONNECTION No.
-
BREAKER |
(15A) |
2 |
1 |
FUSE
250V
6A
|
| 6 |
| 1 | |
X1 | SW2 | 2 3 4 5 | (WHT) | ||
| |||||
REMOTE |
| ||||
|
| ||||
| SWITCH |
| |||
|
| 1 |
|
CN43
SWC |
|
2 | 1 |
P15NBMU
FUSE(15A) |
|
| |
| <w2> |
| |
PULL BOX | L1 TB2 | RED | |
L2 | BLU | ||
| |||
| G | GRN / YLW |
LED1
CND
(RED)
3 2 1
ON OFF | CN32 |
3 |
(WHT) 1 2 3 CNP
See fig : w1
SW5 208V 230V
SW1
ON
3 45 678910 | SW12 SW11 |
12 |
|
OFF |
|
0
0
1ST | DIGIT |
2ND | DIGIT |
3RD | DIGIT |
TO NEXT INDOOR UNIT |
DP