Wired remote controller

Display Section

For purposes of this explanation,

Day-of-Week

all parts of the display are shown

Shows the current day of the week.

as lit. During actual operation, only

 

the relevant items will be lit.

Time/Timer Display

Shows the current time, unless the simple or Auto Off timer is set.

If the simple or Auto Off timer is set, the time to be switched off is shown.

Identifies the current operation

Shows the operating mode, etc. *Multilanguage display is available.

 

TIME SUN MON TUE WED THU FRI SAT

 

TIMER

Hr

ON

 

AFTER

AFTER

OFF

 

ERROR CODE

 

FUNCTION

 

˚F˚C

 

FILTER

“Centrally Controlled” indicator

˚F˚C

 

 

WEEKLY

Indicates that operation from the

ONLY1Hr.

 

SIMPLE

 

AUTO OFF

remote controller has been prohib-

 

 

 

ited by a master controller.

 

 

 

 

 

Up/Down Air Direction indica-

 

Room Temperature display

“Timer is Off” indicator

 

 

 

 

tor

 

Shows the room temperature. The room

 

 

 

 

Shows the direction of the

 

temperature display range is 46~102°F.

 

 

 

 

 

 

Indicates that the timer is off.

 

 

 

outcoming airflow.

 

The display blinks if the temperature

 

 

 

 

 

 

 

is less than 46°F or 102°F or more.

 

 

 

 

 

“One Hour Only” indicator

 

Louver display

 

 

 

 

 

Displayed if the airflow is set to

 

Temperature Setting

 

 

 

low or downward during COOL

 

Indicates the action of the swing louver.

 

 

 

or DRY mode. (Operation varies

 

Does not appear if the louver is not

Shows the target temperature.

 

 

 

according to model.)

 

running.

 

 

 

 

 

The indicator goes off in one hour,

 

(Power On indicator)

 

 

 

 

 

when the airflow direction also

 

 

 

 

 

 

changes.

 

Indicates that the power is on.

“Sensor” indication

Displayed when the remote controller sensor is used.

“Locked” indicator

Indicates that remote controller but- tons have been locked.

“Clean The Filter” indicator

To be displayed on when it is time to clean the filter.

Timer indicators

The indicator comes on if the corre- sponding timer is set.

Fan Speed indicator

Shows the selected fan speed.

Ventilation indicator

Appears when the unit is running in Ventilation mode.

Note:

“PLEASE WAIT” message

This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power failure.

“NOT AVAILABLE” message

This message is displayed if an invalid button is pressed (to operate a function that the indoor unit does not have).

If a single remote controller is used to operate multiple indoor units simultaneously that are different types, this message will not be displayed as far as any of the indoor units is equipped with the function.

4

Page 4
Image 4
Mitsubishi Electronics PMFY-P12NBMU-E1, PMFY-P08NBMU-E1, PMFY-P06NBMU-E1 service manual Display Section, ˚F˚C

PMFY-P08NBMU-E, PMFY-P12NBMU-E1, PMFY-P08NBMU-E1, PMFY-P06NBMU-E, PMFY-P12NBMU-E specifications

Mitsubishi Electronics has long been a pioneer in the field of air conditioning and climate control technologies. Among their impressive lineup of products is the PMFY series, which includes models such as the PMFY-P06NBMU-E1, PMFY-P12NBMU-E, PMFY-P06NBMU-E, PMFY-P08NBMU-E1, and PMFY-P12NBMU-E1. These advanced air conditioning systems are engineered to offer optimal comfort, energy efficiency, and innovative features for both residential and commercial applications.

One of the standout features of the PMFY series is its exceptional energy efficiency. Many models are equipped with advanced inverter technology, which allows for precise temperature control while significantly reducing energy consumption. This results in lower electricity bills and a reduced carbon footprint, making them an environmentally friendly choice for conscientious consumers.

Another key characteristic of the PMFY series is its advanced filtration system. These units are designed to improve indoor air quality by incorporating high-performance filters that effectively remove dust, allergens, and other pollutants. This is especially beneficial for individuals with respiratory conditions, contributing to a healthier indoor environment.

The PMFY models also boast a sleek and modern design, ensuring they blend seamlessly with any interior décor. Compact and lightweight, they can be installed in various settings, maximizing available space without compromising on performance.

Mitsubishi’s proprietary technology features an intelligent control system that allows users to manage their air conditioning units remotely. With options for Wi-Fi connectivity and compatibility with smart home systems, users can easily set schedules, adjust temperatures, and monitor energy usage from their smartphones or tablets.

Noise reduction is another important aspect of the PMFY series. These units operate at whisper-quiet levels, ensuring a peaceful atmosphere in homes and workplaces. This noise control technology is particularly advantageous for bedrooms, offices, and other quiet environments.

Lastly, the PMFY series is designed to be robust and reliable, with components that are engineered for durability and long life. Mitsubishi Electronics stands behind their products with comprehensive warranties, providing peace of mind and exceptional customer service.

In summary, the Mitsubishi Electronics PMFY-P06NBMU-E1, PMFY-P12NBMU-E, PMFY-P06NBMU-E, PMFY-P08NBMU-E1, and PMFY-P12NBMU-E1 are exemplary models that embody the essence of innovation, efficiency, and reliability. They represent the ideal choice for those seeking advanced climate control solutions suitable for a variety of spaces.