C.8.3 Could not Read Configuration file from SERVER1

FastPort could not find the configuration file or did not have the rights to read it.

Configuration file is in the wrong location or misnamed

An incorrect access right was given. Check its access rights:

a.Log in as guest.

b.Go to the /login/milan directory.

c.Type rights and press [Enter]. The system responds with the current rights. Use the Filer command to change the rights if necessary.

C.8.4 Trying to read file SYS:login/milan/FPXXXXXX on SERVER1

FastPort is looking for the configuration file on file server SERVER1.

C.8.5 No such object FAKEQ

There is no queue named FAKEQ. Verify it and the spelling of its queue name.

C.8.6 Failed to login to file server SERVER1 for server FAKEPS

FastPort could not log into a nonexistent file server. The print server has not been created in PCONSOLE. This error may also occur if the user has modified the printer configuration in PCONSOLE. Remove any recent configuration changes made.

C.9 ACT Error Messages

Print server not responding

Power cycle the unit. Wait a minute and try again.

Error setting NVRAM value

Usually due to a stale connection. Exit out of ACT and restart the utility.

MIL-3000FTX Series of FastPort Print Servers

C-11

Page 127
Image 127
Digi MIL-3000FTX manual ACT Error Messages, Could not Read Configuration file from SERVER1, No such object Fakeq