Digi MIL-3000FTX manual Troubleshooting Tips, FastPort does not power up

Models: MIL-3000FTX

1 163
Download 163 pages 45.88 Kb
Page 124
Image 124

C.5 Troubleshooting Tips

This section lists problems and possible solutions for NetWare.

C.5.1 FastPort does not power up

Check the voltage on the power supply. If it is switchable, set it to the correct voltage (e.g., 120 VAC for continental USA).

C.5.2 FastPort does not show up in ACT

Place DIP switch D1 to Off (up) and power cycle the unit.

Examine the front panel LEDs. The Power and Ethernet LEDs blink in normal operating mode.

FastPort uses a Novell Object Identification of 534 (hexadecimal) to register a file server. If the router is set to filter these SAPs, FastPort will not appear when using ACT.

If the Ethernet LED is not blinking, check the transceiver selection on the back of the unit. Link illuminates green if there is a 10BASE-T connection; if not, it will be orange.

Note: After FastPort is rebooted, it take a minutes for it to appear in ACT.

Force a frame type.

NetWare may be disabled. Check the diagnostic test page.

C.5.3 FastPort fails POST after upgrading firmware

This could be due to the relocation of the NVRAM. Reset the unit to factory defaults and try again.

C.5.4 FastPort does not login to bindery Novell 4.x server

Server may not have the bindery emulation mode enabled. Verify that the bindery emulation is enabled: find the following in the autoexec.ncf file in the system directory:

Set Bindery Context=<context>

where <context> is the name of the context to be used by bindery emulation. If not found, bindery emulation is not running. Refer to NetWare’s manual for info. on bindery emulation.

MIL-3000FTX Series of FastPort Print Servers

C-8

Page 124
Image 124
Digi MIL-3000FTX manual Troubleshooting Tips, FastPort does not power up, FastPort does not show up in ACT