Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.

POWER indicator STATUS indicator

POWER STATUS

AUTO POSITION

COMPUTER KEYSTONE VIDEO

Normal condition

POWER

STATUS

CONDITION

NOTE

Steady

Off

Stand-by

 

 

 

red

 

 

 

Steady

Blinking

Lamp stand-by (about 1 minute)

The POWER button cannot be used to

 

switch between on and off.

green

green

 

Steady

Steady

The power is on. (Normal condition)

 

 

 

green

green

 

 

 

 

 

Abnormal condition

POWER STATUS

Steady

green

or

Blinking orange

Steady red

CONDITION

POSSIBLE SOLUTION

Abnormal temperature

 

The ventilation grilles or air filter is clogged with

• Clean the ventilation grilles or air filter.

 

dust or dirt.

• Relocate the projector to a cooler place.

The room temperature is high.

 

 

 

The protection circuit is working or the lamp is in an

Steady red

 

abnormal condition.

Blinking green

 

 

 

 

 

Lamp operation time warning. (Total lamp operation

Steady

Blinking green/red

time reached 1500 hours* while the power was on.)

green

 

 

 

 

Lamp operation time warning. (Total lamp operation

Steady red

Blinking red

time reached 1500 hours* while the power was off.)

Wait until the STATUS indicator goes out, then press the POWER button.

If the above solution is not effective, replace the lamp.

Replace the lamp.

Change with a new lamp if this problem recurs.

 

 

Lamp operation time warning. (Total lamp operation

 

Steady red

Steady red

time reached 2000 hours* while the power was off.)

 

 

 

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

Off

 

 

 

 

 

green/red

 

 

 

 

 

Abnormal.

Contact your dealer.

Steady

or

Blinking

green/red Blinking

* When LAMP MODE of the INSTALLATION menu is set to STANDARD.When it is set to LOW, the duration will be extended.

EN – 28

Page 28
Image 28
Mitsubishi Electronics SL6U user manual Indicators, Normal condition, Abnormal condition, Status Condition, Power Status