Lamp replacement

When the lamp no longer functions, replace it with a new one.

Caution:

• Do not remove the lamp immediately after turn-

ing off the projector, the high temperature of the

lamp can burn you.

• For lamp replacement, press the power button to

power off, then wait for 120 seconds in stand-by

mode to allow the lamp to cool. Then turn off the

main switch, unplug the power cord from the

outlet, and wait one hour so that the lamp is

cooled to the touch.

7.Put the handle back to the holding point.

Make sure that the handle is locked.

8.Tighten up the screws (b) using a phillips screwdriver (+).

9.Tighten up the screws of the lamp lid (a) using a phillips screwdriver (+).

(b)Handle

(a)

• Do not remove the lamp except for replacement.

Careless treatment can cause injury or fire.

• Do not touch the lamp element directly. It may

break and cause you to injure or burn yourself.

• Be sure not to drop the lamp lid screw into the

projector. Also be sure not to insert metal or any

flammable objects, it may cause fire or electric

shock. If any objects are inserted, please unplug

and contact your dealer.

• Install the lamp securely, failure may cause a fire.

• If the light bulb part breaks, some small glass

fragments may fall out through the small cooling

grille, and stick to the inside of projector or the

lamp box. When taking the lamp out, make sure to

turn over the projector and hold the handle of the

lamp box to avoid injury from the glass fragments.

• Never shake the lamp or hold it in front of your face

after removingthe lamp box. The glass fragments

may fall out and cause injuries to your eyes and so

on.

How to reset the operation time meter Plug in the power cord, turn on the main power switch, and reset lamp time by pressing the AUTO POSITION button and POWER button for 3 seconds simultaneously.

Make sure that the STATUS indicator flashed twice and the operation time meter has been reset.

Caution:

Do not spill liquid on the lamp or place it near flammable objects or where children can touch it. Otherwise, it could cause injury or fire.

Be sure that the projector guide is firmly inserted between the right and left lamp guides.

Important:

The projector will not turn on if you do not secure

 

the lamp lid.

You must reset the operation time meter after

 

you replace the lamp.

1.Gently turn the projector over.

2.Loosen the screws of the lamp lid (a) using a phillips screw- driver (+), and remove the lid.

Remove the lamp cover in the direction of the arrow as indicated.

3.Loosen screws (b) using a phillips screwdriver (+).

4.Pull up the handle.

5.Hold onto the projector by the handle as you pull out the lamp.

Pull out the lamp straight upward.

Pull the lamp out of the projector slowly. Should the light bulb be broken, glass fragments will spill out if the lamp is pulled out too quickly.

Once the lamp has been removed, do not spill liquid on it, place it near flammable objects or where children can touch it. Otherwise, it may cause injury or fire.

6.Insert the new lamp securely into the projector body in the right direction.

(a)

(b)Handle

• Do not reset the operation time meter unless the

lamp has been replaced.

Interval of the lamp replacement

The expected lamp lifetime is about 1,500 hours of operation. However, the lamp life may differ accord- ing to the operat-ing environment and may be shorter than 1,500 hours. Decreases in brightness will indicate that the projector lamp needs to be replaced. When lamp operation time exceeds 1,000 hours, the indicator will flash alternately between green and red (while the lamp is in operation; when the lamp is not in operation, the STATUS indicator will appear red only). When the lamp has been used for about 1,400 hours, the message “LAMP!!.” will appear on the screen for one minute everytime the power is turned on. When the lamp has been used for about 1,500 hours, the projector will automatically shut off for safety and the power and STATUS indicators light will be red. The projector cannot be used until the lamp has been replaced and operation timer has been reset.

Caution:

The lamp is fragile. If broken, be careful not to cut yourself with glass fragments.

The replacement span of the lamp depends on the environment. For replacement lamps, please contact your dealer.

The projector automatically shuts off when the lamp life exceeds 1,500 hours and cannot be used until the lamp is replaced and the internal timer is reset.

EN – 22

Page 22
Image 22