How to set the grade

Use ASCII letters code to set the grade for setting data. Please refer to the table below for HEX code.

ASCII

'+'

'-'

'0'

'1'

'2'

'3'

'4'

'5'

'6'

'7'

'8'

'9'

HEX

2Bh

2Dh

30h

31h

32h

33h

34h

35h

36h

37h

38h

39h

[Example 1]

Set the MUTE to ON.

 

 

 

Sending commands

Status code from

Meaning

 

 

from the PC etc.

projector

 

 

30 30 4D 55 54 45 31 0D

 

Command for setting the

 

'0' '0' 'M' 'U' 'T' 'E' '1' ' '

 

MUTE to ON

 

 

 

 

 

 

 

 

30 30 4D 55 54 45 31 0D

Command received

 

 

 

'0' '0' 'M' 'U' 'T' 'E' '1' ' '

(Command echo back)

 

 

 

 

 

[Example 2] The TINT was set to +10 when the setting status was confirmed.

Sending commands

Status code from

Meaning

from the PC etc.

projector

 

30 30 53 0D

 

Command to confirm

'0' '0' 'S' ' '

 

setting of TINT

 

 

 

 

30 30 53 2B 31 30 0D

Command (setting of TINT

 

'0' '0' 'S' '+' '1' '0' ' '

is +10) carried out

 

 

 

4

Page 34
Image 34
Mitsubishi Electronics XD200U, SD200U user manual Example Set the Mute to on