INSTRUCTIONS FOR THE INSTALLER
Safety Advice
This cooker must be installed in accordance with the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.
Location
This cooker has been registered as a "Class X" appliance according to Fire Risk Regulations. Any adjacent cabinets or walls must not exceed the cooker's height.
The cooker may be located in a kitchen, a kitchen/diner or bed sitting room, but not in
a bathroom or shower room.
The minimum distance combustible material can be fitted above the cooker in line with the edges of the cooker is 420 mm. If it is fitted below 420
mm.a space of 50 mm. must be allowed from the edges of
the cooker.
The minimum distance combustible material can be fitted directly above the cooker is 700 mm. The adjacent furniture panels have to be heat proof or protected by such material.
Dimensions
Height
Depth
Width
Oven Capacity
Hob
Front left heating plate (rapid)
Back left heating plate (normal)
Back right heating plate (normal) Front right heating plate (normal) Total Rating
TECHNICAL DATA
| Oven | 1750 W | |
900mm | Conventional (both |
|
|
600mm | elements) | 750 | W |
500mm | Top element | 1000 | W |
1.942 Cu. ft | Bottom element |
|
|
Supply voltage (50Hz)
2000 W
1000 W
1500 W
1000 W
5500 W
17 | 16011105/R3 |