Moffat ESV5060W Supply Cable Specifications, Electrical Connections, This Cooker Must Be Earthed

Models: ESV5060W

1 20
Download 20 pages 650 b
Page 18
Image 18
ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

Any electrical work required to install this hob should be carried out by a qualified

electrician or competent person, in accordance with the current regulations.

THIS COOKER MUST BE

EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 230-240V 50Hz AC

electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the

hob.

The cooker is supplied without a supply cord. A supply cord must be fitted, in accordance with the specification given in the relevant tables.

1.Loosen the two fixing screws securing the back protective screen of the cooker, then lift it up and remove it. This will expose the terminal block on the right bottom corner.

2.Loosen the two cable clamp screws and lift the top section of the clamp enough to allow the cable to be passed through.

3.Connect the red (live) wire to the terminal which is marked with the letter "L".

4.Connect the black (neutral) wire to the terminal which is marked with the letter "N".

5.After fitting a green or yellow/green sleeve over the bare copper wire (earth wire),

connect the exposed end to the terminal

which is marked with the earth symbol THIS COOKER MUST BE or with the letter "E" coloured green and

yellow.

NOTE:

The earth wire should be about 2 cm. longer than the live and neutral wires.

6.Secure the cable by means of the clamp screws and refit the back protective screen.

The cooker should be connected to a double pole switch with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations. The switch should be sited within 2m of the hob and be easily accessible upon completion of the installation.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg.C.

Supply Cable Specifications

For UK use only

Connection

Min. size

Fuse

Via

Cable

 

Cooker

6 mm²

30 A

Control

Twin &

 

Circuit

Earth

 

For European use only

 

 

 

 

Min. Size

Cable / flex

Fuse

Cable

type

 

3 x 2.5 mm²

H05 W-F

30 A

4

3

2

5

1

6

18

16011105/R3

19

 

Page 18
Image 18
Moffat ESV5060W Supply Cable Specifications, Electrical Connections, This Cooker Must Be Earthed, electrical supply, Fuse