Adjustment of minimum level

Oven burner

Remove the top pan support as well as the burner caps and the burner crowns.

Unscrew and remove the 2 top plate fixing screws and remove the top plate.

Light the burner knob on position 9 and leave the oven door closed for about 10 min.

Turn the knob slowly to position 1.

Pull off the knob to adjust minimum flow.

Unscrew or screw the by-pass screw (is it above of tap shaft) until a regular small flame is reached.

For LPG screw completely the by-pass

screw.

The flame shouldn’t extinguish when closing the oven door.

Grill burner

The grill temperature cannot be adjusted. To obtain a lower temperature or slower cooking time the grill pan must be lowered away fron the flame.

AFTER COMPLETION OF ANY REPAIRS, ADJUSTMENTS OR CONVERSION THE STATUTORY SAFETY TESTS MUST BE CARRIED OUT.