Moffat MEH 631 Instructions for the Installer, Engineers technical data, Heating elements Ratings

Models: MEH 631

1 12
Download 12 pages 34.38 Kb
Page 6
Image 6
Instructions for the Installer

Instructions for the Installer

This hob must be installed by qualified personnel to the relevant

British Standards. - The manufacturer will not accept liability, should the following instructions or any of the other safety instructions incorporated in this book be ignored.

Engineers technical data

Overall dimensions

Cut out dimensions

Width:

580 mm.

Width:

550 mm.

Depth:

500 mm.

Depth:

470 mm.

Heating elements Ratings

Normal front left hotplate

Ø 180 mm

1500 W

 

Normal back left hotplate

Ø 145 mm

1000 W

 

Rapid front right hotplate

Ø 145 mm

1500 W

 

Rapid back right hotplate

Ø 180 mm

2000 W

 

Total rating

6000 W

Supply connections

Electric:

230V 50Hz AC electrical supply.

When the hob is first installed

 

 

Once the hob has been installed, it

 

 

is important to remove any

 

 

protective materials, which were put on in

 

 

the factory.

Cut Out Size

 

 

 

FO 2098

 

0

 

 

7

30

 

4

 

 

550

 

Dimensions are given in mm.