Instructions for the Installer
This hob must be installed by qualified personnel to the relevant
British Standards. - The manufacturer will not accept liability, should the following instructions or any of the other safety instructions incorporated in this book be ignored.
Engineers technical data
Overall dimensions | Cut out dimensions | ||
Width: | 580 mm. | Width: | 550 mm. |
Depth: | 500 mm. | Depth: | 470 mm. |
Heating elements Ratings
Normal front left hotplate | Ø 180 mm |
1500 W |
|
Normal back left hotplate | Ø 145 mm |
1000 W |
|
Rapid front right hotplate | Ø 145 mm |
1500 W |
|
Rapid back right hotplate | Ø 180 mm |
2000 W |
|
Total rating | 6000 W |
Supply connections
Electric:
230V 50Hz AC electrical supply.
When the hob is first installed |
|
|
Once the hob has been installed, it |
|
|
is important to remove any |
|
|
protective materials, which were put on in |
|
|
the factory. | Cut Out Size | |
| ||
|
| FO 2098 |
| 0 |
|
| 7 | 30 |
| 4 | |
|
| 550 |
| Dimensions are given in mm. |
6